Audible/Visible Notification Product Line

SpeakersSpeaker StrobesHornsStrobesHorn StrobesMini-HornsChimesChime Strobes
Sync-ModulesExitPointAccessoriesSpeaker AccessoriesMass Notification/General Evacuation

Audible Visible Notification
Search for: SpectrAlert Advance

SpectrAlert Advance

MDL3R
MDL3R MDL3R
MDL3R Data Sheet Data Sheet (pdf)
MDL3R Installation Instructions Installation Instructions (pdf)
MDL3R Engineering Specs Engineering Specs
The SpectrAlert Advance MDL3R is a red, 12/24 volt Sync-Circuit module.

MDL3W
MDL3W MDL3W
MDL3W Data Sheet Data Sheet (pdf)
MDL3W Installation Instructions Installation Instructions (pdf)
MDL3W Engineering Specs Engineering Specs
The SpectrAlert Advance MDL3W is a white, 12/24 volt Sync-Circuit module.

P2WHK
P2WHK P2WHK
P2WHK Data Sheet Data Sheet (pdf)
P2WHK Installation Instructions Installation Instructions (pdf)
P2WHK Engineering Specs Engineering Specs
The SpectrAlert Advance P2WHK is a white, two-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.

P2WK
P2WK P2WK
P2WK Data Sheet Data Sheet (pdf)
P2WK Installation Instructions Installation Instructions (pdf)
P2WK Engineering Specs Engineering Specs
The SpectrAlert Advance P2WK is a white, two-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.

P4WK
P4WK P4WK
P4WK Data Sheet Data Sheet (pdf)
P4WK Installation Instructions Installation Instructions (pdf)
P4WK Engineering Specs Engineering Specs
The SpectrAlert Advance P4WK is a white, four-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.

PC2WHK
PC2WHK PC2WHK
PC2WHK Data Sheet Data Sheet (pdf)
PC2WHK Installation Instructions Installation Instructions (pdf)
PC2WHK Engineering Specs Engineering Specs
The SpectrAlert Advance PC2WHK is a white, two-wire, outdoor, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.

PC2WK
PC2WK PC2WK
PC2WK Data Sheet Data Sheet (pdf)
PC2WK Installation Instructions Installation Instructions (pdf)
PC2WK Engineering Specs Engineering Specs
The SpectrAlert Advance PC2WK is a white, two-wire, ceiling-mount outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.

PC4WHK
PC4WHK PC4WHK
PC4WHK Data Sheet Data Sheet (pdf)
PC4WHK Installation Instructions Installation Instructions (pdf)
PC4WHK Engineering Specs Engineering Specs
The SpectrAlert Advance PC4WHK is a white, four-wire, outdoor, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.

PC4WK
PC4WK PC4WK
PC4WK Data Sheet Data Sheet (pdf)
PC4WK Installation Instructions Installation Instructions (pdf)
PC4WK Engineering Specs Engineering Specs
The SpectrAlert Advance PC4WK is a white, four-wire, outdoor, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.

SA-WBBCW
SA-WBBCW SA-WBBCW
SA-WBBCW Data Sheet Data Sheet (pdf)
SA-WBBCW Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SA-WBBCW is a white separate ship, ceiling-mount, outdoor back box.

SA-WBBW
SA-WBBW SA-WBBW
SA-WBBW Data Sheet Data Sheet (pdf)
SA-WBBW Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SA-WBBW is a white separate ship, wall-mount, outdoor back box.

SCW-CLR-ALERT
SCW-CLR-ALERT SCW-CLR-ALERT
SCW-CLR-ALERT Data Sheet Data Sheet (pdf)
SCW-CLR-ALERT Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SCW-CLR-ALERT is a white strobe with standard cd and a clear lens designed for mass notification applications.

SCWHK
SCWHK SCWHK
SCWHK Data Sheet Data Sheet (pdf)
SCWHK Installation Instructions Installation Instructions (pdf)
SCWHK Engineering Specs Engineering Specs
SpectrAlert Advance SCWHK is a white, outdoor ceiling-mount strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.

SCWK
SCWK SCWK
SCWK Data Sheet Data Sheet (pdf)
SCWK Installation Instructions Installation Instructions (pdf)
SCWK Engineering Specs Engineering Specs
SpectrAlert Advance SCWK is a white, outdoor ceiling-mount strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.

SPRK-R
SPRK-R SPRK-R
SPRK-R Data Sheet Data Sheet (pdf)
SPRK-R Installation Instructions Installation Instructions (pdf)
SPRK-R Engineering Specs Engineering Specs
The SpectrAlert Advance SPRK-R (replacement model) is a red, outdoor, wall-mount speaker. Offers mounting plate only – no back box included.

SPSCW-CLR-ALERT
SPSCW-CLR-ALERT SPSCW-CLR-ALERT
SPSCW-CLR-ALERT Data Sheet Data Sheet (pdf)
SPSCW-CLR-ALERT Installation Instructions Installation Instructions (pdf)
SPSCW-CLR-ALERT Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCW-CLR-ALERT is a white speaker strobe with standard cd and a clear lens designed for mass notification applications.

SPSCWV-P
SPSCWV-P SPSCWV-P
SPSCWV-P Data Sheet Data Sheet (pdf)
SPSCWV-P Installation Instructions Installation Instructions (pdf)
SPSCWV-P Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCWV-P is an umarked, white speaker strobe for ceiling installations with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT, or AGENT that can be manually applied to the product housing.

SPSRK-R
SPSRK-R SPSRK-R
SPSRK-R Data Sheet Data Sheet (pdf)
SPSRK-R Installation Instructions Installation Instructions (pdf)
SPSRK-R Engineering Specs Engineering Specs
The SpectrAlert Advance SPSRK-R (replacement model) is a red, outdoor speaker strobe for wall installation with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Offers mounting plate only – no back box included.

SPSW-ALERT
SPSW-ALERT SPSW-ALERT
SPSW-ALERT Data Sheet Data Sheet (pdf)
SPSW-ALERT Installation Instructions Installation Instructions (pdf)
SPSW-ALERT Engineering Specs Engineering Specs
The SpectrAlert Advance SPSW-ALERT is a white speaker strobe with standard cd and an amber lens designed for mass notification applications

SPSW-CLR-ALERT
SPSW-CLR-ALERT SPSW-CLR-ALERT
SPSW-CLR-ALERT Data Sheet Data Sheet (pdf)
SPSW-CLR-ALERT Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SPSW-CLR-ALERT is a white speaker strobe with standard cd and a clear lens designed for mass notification applications.

SPSWK-R
SPSWK-R SPSWK-R
SPSWK-R Data Sheet Data Sheet (pdf)
SPSWK-R Installation Instructions Installation Instructions (pdf)
SPSWK-R Engineering Specs Engineering Specs
The SpectrAlert Advance SPSWK-R (replacement model) is a white, outdoor speaker strobe for wall installation with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Offers mounting plate only – no back box included.

SPWK-R
SPWK-R SPWK-R
SPWK-R Data Sheet Data Sheet (pdf)
SPWK-R Installation Instructions Installation Instructions (pdf)
SPWK-R Engineering Specs Engineering Specs
The SpectrAlert Advance SPWK-R (replacement model) is a white, outdoor, wall-mount speaker. Offers mounting plate only – no back box included.

SW-CLR-ALERT
SW-CLR-ALERT SW-CLR-ALERT
SW-CLR-ALERT Data Sheet Data Sheet (pdf)
SW-CLR-ALERT Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SW-CLR-ALERT is a white strobe with standard cd and a clear lens designed for mass notification applications.

SWHK
SWHK SWHK
SWHK Data Sheet Data Sheet (pdf)
SWHK Installation Instructions Installation Instructions (pdf)
SWHK Engineering Specs Engineering Specs
The SpectrAlert Advance SWHK is a white, outdoor strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.

SWK
SWK SWK
SWK Data Sheet Data Sheet (pdf)
SWK Installation Instructions Installation Instructions (pdf)
SWK Engineering Specs Engineering Specs
The SpectrAlert Advance SWK is a white, outdoor strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.

SPW
SPW SPW
SPW Data Sheet Data Sheet (pdf)
SPW Installation Instructions Installation Instructions (pdf)
SPW Engineering Specs Engineering Specs
The SpectrAlert Advance SPW is a white speaker for wall installation.

BBSC-2
BBSC-2 BBSC-2
BBSC-2 Data Sheet Data Sheet (pdf)
The SpectrAlert Advance BBSC-2 is a red back box skirt for ceiling installations.

BBSCW-2
BBSCW-2 BBSCW-2
BBSCW-2 Data Sheet Data Sheet (pdf)
The SpectrAlert Advance BBSCW-2 is a white back box skirt for ceiling installations.

BBS-2
BBS-2 BBS-2
BBS-2 Data Sheet Data Sheet (pdf)
The SpectrAlert Advance BBS-2 is a red back box skirt for wall installations.

BBSW-2
BBSW-2 BBSW-2
BBSW-2 Data Sheet Data Sheet (pdf)
The SpectrAlert Advance BBSW-2 is a white back box skirt for wall installations.

LENS-A
LENS-A LENS-A
LENS-A Data Sheet Data Sheet (pdf)
LENS-A Installation Instructions Installation Instructions (pdf)
Wall mount lens attachment, amber

LENS-AC
LENS-AC LENS-AC
LENS-AC Data Sheet Data Sheet (pdf)
LENS-AC Installation Instructions Installation Instructions (pdf)
Ceiling mount lens attachment, amber

LENS-B
LENS-B LENS-B
LENS-B Data Sheet Data Sheet (pdf)
LENS-B Installation Instructions Installation Instructions (pdf)
Wall mount lens attachment, blue

LENS-BC
LENS-BC LENS-BC
LENS-BC Data Sheet Data Sheet (pdf)
LENS-BC Installation Instructions Installation Instructions (pdf)
Ceiling mount lens attachment, blue

LENS-G
LENS-G LENS-G
LENS-G Data Sheet Data Sheet (pdf)
LENS-G Installation Instructions Installation Instructions (pdf)
Wall mount lens attachment, green

LENS-GC
LENS-GC LENS-GC
LENS-GC Data Sheet Data Sheet (pdf)
LENS-GC Installation Instructions Installation Instructions (pdf)
Ceiling mount lens attachment, green

LENS-R
LENS-R LENS-R
LENS-R Data Sheet Data Sheet (pdf)
LENS-R Installation Instructions Installation Instructions (pdf)
Wall mount lens attachment, red

LENS-RC
LENS-RC LENS-RC
LENS-RC Data Sheet Data Sheet (pdf)
LENS-RC Installation Instructions Installation Instructions (pdf)
Ceiling mount lens attachment, red

MP120K
MP120K MP120K
MP120K Data Sheet Data Sheet (pdf)
MP120K Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance MP120K mounting plate is designed to use 120 VAC to power SpectrAlert Advance horns, strobes, horn⁄strobes, chimes and chime⁄strobes.

SA-WBB
SA-WBB SA-WBB
SA-WBB Data Sheet Data Sheet (pdf)
SA-WBB Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SA-WBB is a separate ship, wall-mount, outdoor back box.

SA-WBBC
SA-WBBC SA-WBBC
SA-WBBC Data Sheet Data Sheet (pdf)
SA-WBBC Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SA-WBBC is a separate ship, ceiling-mount, outdoor back box.

CHSR
CHSR CHSR
CHSR Data Sheet Data Sheet (pdf)
CHSR Installation Instructions Installation Instructions (pdf)
CHSR Engineering Specs Engineering Specs
The SpectrAlert Advance CHSR is a red chime/strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110, and 115 cd for ceiling or wall installation.

TR-HS
TR-HS TR-HS
TR-HS Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance TR-HS is a red trim ring for use with wall mounted devices. Allows 4-wire devices to mount to a single gang back box.

CHSW
CHSW CHSW
CHSW Data Sheet Data Sheet (pdf)
CHSW Installation Instructions Installation Instructions (pdf)
CHSW Engineering Specs Engineering Specs
The SpectrAlert Advance CHSW is a white chime/strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110, and 115 cd for ceiling or wall installation.

TRC-HS
TRC-HS TRC-HS
TRC-HS Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance TRC-HS is a red trim ring for use with ceiling mounted devices. Allows 4-wire devices to mount to a single gang back box.

CHW
CHW CHW
CHW Data Sheet Data Sheet (pdf)
CHW Installation Instructions Installation Instructions (pdf)
CHW Engineering Specs Engineering Specs
The SpectrAlert Advance CHW is a white chime for ceiling or wall installation.

TRCW-HS
TRCW-HS TRCW-HS
TRCW-HS Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance TRCW-HS is a white trim ring for ceiling mounted devices. Allows 4-wire devices to mount to a single gang back box.

TRW-HS
TRW-HS TRW-HS
TRW-HS Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance TRW-HS is a white trim ring for use with wall mounted devices. Allows 4-wire devices to mount to a single gang back box.

HR
HR HR
HR Data Sheet Data Sheet (pdf)
HR Installation Instructions Installation Instructions (pdf)
HR Engineering Specs Engineering Specs
The SpectrAlert Advance HR is a red, 12/24 volt horn for ceiling or wall installation.

HRK
HRK HRK
HRK Data Sheet Data Sheet (pdf)
HRK Installation Instructions Installation Instructions (pdf)
HRK Engineering Specs Engineering Specs
The SpectrAlert Advance HRK is a red, 12/24 volt horn for outdoor ceiling or wall installation.

HRK-R
HRK-R HRK-R
HRK-R Data Sheet Data Sheet (pdf)
HRK-R Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance HRK-R (replacement model) is a red, 12/24-volt horn for outdoor ceiling or wall installation. Offers mounting plate only - no back box included.

HW
HW HW
HW Data Sheet Data Sheet (pdf)
HW Installation Instructions Installation Instructions (pdf)
HW Engineering Specs Engineering Specs
The SpectrAlert Advance HW is a white, 12/24-volt horn for ceiling or wall installation.

P2R
P2R P2R
P2R Data Sheet Data Sheet (pdf)
P2R Installation Instructions Installation Instructions (pdf)
P2R Engineering Specs Engineering Specs
The SpectrAlert Advance P2R is a red, two-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

P2R-P
P2R-P P2R-P
P2R-P Data Sheet Data Sheet (pdf)
P2R-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance P2R-P is an unmarked, red, two-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

P2R-SP
P2R-SP P2R-SP
P2R-SP Data Sheet Data Sheet (pdf)
P2R-SP Installation Instructions Installation Instructions (pdf)
Marked with "FUEGO," the SpectrAlert Advance P2R-SP is a red, two-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

P2RH
P2RH P2RH
P2RH Data Sheet Data Sheet (pdf)
P2RH Installation Instructions Installation Instructions (pdf)
P2RH Engineering Specs Engineering Specs
The SpectrAlert Advance P2RH is a red, two-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.

P2RK
P2RK P2RK
P2RK Data Sheet Data Sheet (pdf)
P2RK Installation Instructions Installation Instructions (pdf)
P2RK Engineering Specs Engineering Specs
The SpectrAlert Advance P2RK is a red, two-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.

P2RK-P
P2RK-P P2RK-P
P2RK-P Data Sheet Data Sheet (pdf)
P2RK-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance P2RK-P is an unmarked, red, two-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

P2RK-R
P2RK-R P2RK-R
P2RK-R Data Sheet Data Sheet (pdf)
P2RK-R Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance P2RK-R (replacement model) is a red, two-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Offers mounting plate only - no back box included.

P2RHK
P2RHK P2RHK
P2RHK Data Sheet Data Sheet (pdf)
P2RHK Installation Instructions Installation Instructions (pdf)
P2RHK Engineering Specs Engineering Specs
The SpectrAlert Advance P2RHK is a red, two-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.

P2RHK-P
P2RHK-P P2RHK-P
P2RHK-P Data Sheet Data Sheet (pdf)
P2RHK-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance P2RHK-P is an unmarked red, two-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

P2RHK-R
P2RHK-R P2RHK-R
P2RHK-R Data Sheet Data Sheet (pdf)
P2RHK-R Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance P2RHK-R (replacement model) is a red, two-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Offers mounting plate only - no back box included.

P2W
P2W P2W
P2W Data Sheet Data Sheet (pdf)
P2W Installation Instructions Installation Instructions (pdf)
P2W Engineering Specs Engineering Specs
The SpectrAlert Advance P2W is a white, two-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

P2W-P
P2W-P P2W-P
P2W-P Data Sheet Data Sheet (pdf)
P2W-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance P2W-P is an unmarked, white, two-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

P2WH
P2WH P2WH
P2WH Data Sheet Data Sheet (pdf)
P2WH Installation Instructions Installation Instructions (pdf)
P2WH Engineering Specs Engineering Specs
The SpectrAlert Advance P2WH is a white, two-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.

P2WH-P
P2WH-P P2WH-P
P2WH-P Data Sheet Data Sheet (pdf)
P2WH-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance P2WH-P is an unmarked, white, two-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

P2WK-P
P2WK-P P2WK-P
P2WK-P Data Sheet Data Sheet (pdf)
P2WK-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance P2WK-P is an unmarked, white, two-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

P2WHK-P
P2WHK-P P2WHK-P
P2WHK-P Data Sheet Data Sheet (pdf)
P2WHK-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance P2WHK-P is an unmarked, white, two-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

P4R
P4R P4R
P4R Data Sheet Data Sheet (pdf)
P4R Installation Instructions Installation Instructions (pdf)
P4R Engineering Specs Engineering Specs
The SpectrAlert Advance P4R is a red, four-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

P4RH
P4RH P4RH
P4RH Data Sheet Data Sheet (pdf)
P4RH Installation Instructions Installation Instructions (pdf)
P4RH Engineering Specs Engineering Specs
The SpectrAlert Advance P4RH is a red, four-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.

P4RK
P4RK P4RK
P4RK Data Sheet Data Sheet (pdf)
P4RK Installation Instructions Installation Instructions (pdf)
P4RK Engineering Specs Engineering Specs
The SpectrAlert Advance P4RK is a red, four-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

P4RK-R
P4RK-R P4RK-R
P4RK-R Data Sheet Data Sheet (pdf)
P4RK-R Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance P4RK-R (replacement model) is a red, four-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Offers mounting plate only - no back box included.

P4W
P4W P4W
P4W Data Sheet Data Sheet (pdf)
P4W Installation Instructions Installation Instructions (pdf)
P4W Engineering Specs Engineering Specs
The SpectrAlert Advance P4W is a white, four-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

P4W-P
P4W-P P4W-P
P4W-P Data Sheet Data Sheet (pdf)
P4W-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance P4W-P is an unmarked, white, four-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

PC2R
PC2R PC2R
PC2R Data Sheet Data Sheet (pdf)
PC2R Installation Instructions Installation Instructions (pdf)
PC2R Engineering Specs Engineering Specs
The SpectrAlert Advance PC2R is a red, two-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

PC2R-P
PC2R-P PC2R-P
PC2R-P Data Sheet Data Sheet (pdf)
PC2R-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance PC2R-P is an unmarked, red, two-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

PC2RH
PC2RH PC2RH
PC2RH Data Sheet Data Sheet (pdf)
PC2RH Installation Instructions Installation Instructions (pdf)
PC2RH Engineering Specs Engineering Specs
The SpectrAlert Advance PC2RH is a red, two-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.

PC2RK
PC2RK PC2RK
PC2RK Data Sheet Data Sheet (pdf)
PC2RK Installation Instructions Installation Instructions (pdf)
PC2RK Engineering Specs Engineering Specs
The SpectrAlert Advance PC2RK is a red, two-wire, ceiling-mount, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.

PC2RHK
PC2RHK PC2RHK
PC2RHK Data Sheet Data Sheet (pdf)
PC2RHK Installation Instructions Installation Instructions (pdf)
PC2RHK Engineering Specs Engineering Specs
The SpectrAlert Advance PC2RHK is a red, two-wire, ceiling-mount, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.

PC2W
PC2W PC2W
PC2W Data Sheet Data Sheet (pdf)
PC2W Installation Instructions Installation Instructions (pdf)
PC2W Engineering Specs Engineering Specs
The SpectrAlert Advance PC2W is a white, two-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

PC2W-P
PC2W-P PC2W-P
PC2W-P Data Sheet Data Sheet (pdf)
PC2W-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance PC2W-P is an unmarked, white, two-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

PC2W-SP
PC2W-SP PC2W-SP
PC2W-SP Data Sheet Data Sheet (pdf)
PC2W-SP Installation Instructions Installation Instructions (pdf)
Marked with "FUEGO," the SpectrAlert Advance PC2W-SP is a white, two-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

PC2WH
PC2WH PC2WH
PC2WH Data Sheet Data Sheet (pdf)
PC2WH Installation Instructions Installation Instructions (pdf)
PC2WH Engineering Specs Engineering Specs
The SpectrAlert Advance PC2WH is a white, two-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.

PC2WH-P
PC2WH-P PC2WH-P
PC2WH-P Data Sheet Data Sheet (pdf)
PC2WH-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance PC2WH-P is an unmarked, white, two-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

PC4R
PC4R PC4R
PC4R Data Sheet Data Sheet (pdf)
PC4R Installation Instructions Installation Instructions (pdf)
PC4R Engineering Specs Engineering Specs
The SpectrAlert Advance PC4R is a red, four-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

PC4RH
PC4RH PC4RH
PC4RH Data Sheet Data Sheet (pdf)
PC4RH Installation Instructions Installation Instructions (pdf)
PC4RH Engineering Specs Engineering Specs
The SpectrAlert Advance PC4RH is a red, four-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.

SCR
SCR SCR
SCR Data Sheet Data Sheet (pdf)
SCR Installation Instructions Installation Instructions (pdf)
SCR Engineering Specs Engineering Specs
The SpectrAlert Advance SCR is a red, ceiling-mount strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SCRH
SCRH SCRH
SCRH Data Sheet Data Sheet (pdf)
SCRH Installation Instructions Installation Instructions (pdf)
SCRH Engineering Specs Engineering Specs
The SpectrAlert Advance SCRH is a red, ceiling-mount strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.

SCRHK
SCRHK SCRHK
SCRHK Data Sheet Data Sheet (pdf)
SCRHK Installation Instructions Installation Instructions (pdf)
SCRHK Engineering Specs Engineering Specs
The SpectrAlert Advance SCRHK is a red, ceiling-mount, outdoor strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.

SCRK
SCRK SCRK
SCRK Data Sheet Data Sheet (pdf)
SCRK Installation Instructions Installation Instructions (pdf)
SCRK Engineering Specs Engineering Specs
The SpectrAlert Advance SCRK is a red, ceiling-mount, outdoor strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SCW
SCW SCW
SCW Data Sheet Data Sheet (pdf)
SCW Installation Instructions Installation Instructions (pdf)
SCW Engineering Specs Engineering Specs
The SpectrAlert Advance SCW is a white, ceiling-mount strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SCW-P
SCW-P SCW-P
SCW-P Data Sheet Data Sheet (pdf)
SCW-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SCW-P is an unmarked, white, ceiling-mount strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

SCWH
SCWH SCWH
SCWH Data Sheet Data Sheet (pdf)
SCWH Installation Instructions Installation Instructions (pdf)
SCWH Engineering Specs Engineering Specs
The SpectrAlert Advance SCWH is a white, ceiling-mount strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.

SR
SR SR
SR Data Sheet Data Sheet (pdf)
SR Installation Instructions Installation Instructions (pdf)
SR Engineering Specs Engineering Specs
The SpectrAlert Advance SR is a red strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SR-P
SR-P SR-P
SR-P Data Sheet Data Sheet (pdf)
SR-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SR-P is an unmarked, red strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

SR-SP
SR-SP SR-SP
SR-SP Data Sheet Data Sheet (pdf)
SR-SP Installation Instructions Installation Instructions (pdf)
Marked with "FUEGO," the SpectrAlert Advance SR-SP is a red strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SRH
SRH SRH
SRH Data Sheet Data Sheet (pdf)
SRH Installation Instructions Installation Instructions (pdf)
SRH Engineering Specs Engineering Specs
The SpectrAlert Advance SRH is a red strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.

SRH-P
SRH-P SRH-P
SRH-P Data Sheet Data Sheet (pdf)
SRH-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SRH-P is an unmarked, red strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

SRHK
SRHK SRHK
SRHK Data Sheet Data Sheet (pdf)
SRHK Installation Instructions Installation Instructions (pdf)
SRHK Engineering Specs Engineering Specs
The SpectrAlert Advance SRHK is a red, outdoor strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.

SRHK-P
SRHK-P SRHK-P
SRHK-P Data Sheet Data Sheet (pdf)
SRHK-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SRHK-P is an unmarked, red, outdoor strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

SRHK-R
SRHK-R SRHK-R
SRHK-R Data Sheet Data Sheet (pdf)
SRHK-R Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SRHK-R (replacement model) is a red, outdoor strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Offers mounting plate only - no back box included.

SRK
SRK SRK
SRK Data Sheet Data Sheet (pdf)
SRK Installation Instructions Installation Instructions (pdf)
SRK Engineering Specs Engineering Specs
The SpectrAlert Advance SRK is a red, outdoor strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SRK-P
SRK-P SRK-P
SRK-P Data Sheet Data Sheet (pdf)
SRK-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SRK-P is an unmarked, red, wall-mount outdoor strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

SWK-P
SWK-P SWK-P
SWK-P Data Sheet Data Sheet (pdf)
SWK-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SWK-P is an unmarked, white, outdoor strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

SWHK-P
SWHK-P SWHK-P
SWHK-P Data Sheet Data Sheet (pdf)
SWHK-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SWHK-P is an unmarked, white, outdoor strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

SRK-R
SRK-R SRK-R
SRK-R Data Sheet Data Sheet (pdf)
SRK-R Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SRK-R (replacement model) is a red, outdoor strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Offers mounting plate only - no back box included.

SW
SW SW
SW Data Sheet Data Sheet (pdf)
SW Installation Instructions Installation Instructions (pdf)
SW Engineering Specs Engineering Specs
The SpectrAlert Advance SW is a white strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SW-P
SW-P SW-P
SW-P Data Sheet Data Sheet (pdf)
SW-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SW-P is an unmarked, white strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.

SWH
SWH SWH
SWH Data Sheet Data Sheet (pdf)
SWH Installation Instructions Installation Instructions (pdf)
SWH Engineering Specs Engineering Specs
The SpectrAlert Advance SWH is a white strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.

SWH-P
SWH-P SWH-P
SWH-P Data Sheet Data Sheet (pdf)
SWH-P Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SWH-P is an unmarked, white strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.

CHR
CHR CHR
CHR Data Sheet Data Sheet (pdf)
CHR Installation Instructions Installation Instructions (pdf)
CHR Engineering Specs Engineering Specs
The SpectrAlert Advance CHR is a red chime for ceiling or wall installation.

P2RHK-120
P2RHK-120 P2RHK-120
P2RHK-120 Data Sheet Data Sheet (pdf)
P2RHK-120 Installation Instructions Installation Instructions (pdf)
P2RHK-120 Engineering Specs Engineering Specs
The SpectrAlert Advance P2RHK-120 is a red, 120 V, selectable-output, outdoor horn strobe.

MHR
MHR MHR
MHR Data Sheet Data Sheet (pdf)
MHR Installation Instructions Installation Instructions (pdf)
MHR Engineering Specs Engineering Specs
The SpectrAlert® Advance MHR is the red, 12/24-volt mini-horn used where a smaller notification device is desired.

MHW
MHW MHW
MHW Data Sheet Data Sheet (pdf)
MHW Installation Instructions Installation Instructions (pdf)
MHW Engineering Specs Engineering Specs
The SpectrAlert® Advance MHW is the white, 12/24-volt mini-horn used where a smaller notification device is desired.

SW-ALERT
SW-ALERT SW-ALERT
SW-ALERT Data Sheet Data Sheet (pdf)
SW-ALERT Installation Instructions Installation Instructions (pdf)
SW-ALERT Engineering Specs Engineering Specs
The SpectrAlert Advance SW-ALERT is a white strobe with standard cd and an amber lens designed for mass notification applications.

SWH-ALERT
SWH-ALERT SWH-ALERT
SWH-ALERT Data Sheet Data Sheet (pdf)
SWH-ALERT Installation Instructions Installation Instructions (pdf)
SWH-ALERT Engineering Specs Engineering Specs
The SpectrAlert Advance SWH-ALERT is a white strobe with high cd and an amber lens designed for mass notification applications.

PC4W
PC4W PC4W
PC4W Data Sheet Data Sheet (pdf)
PC4W Installation Instructions Installation Instructions (pdf)
PC4W Engineering Specs Engineering Specs
The SpectrAlert Advance PC4W is a white, four-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SPR
SPR SPR
SPR Data Sheet Data Sheet (pdf)
SPR Installation Instructions Installation Instructions (pdf)
SPR Engineering Specs Engineering Specs
The SpectrAlert Advance SPR is a red speaker for wall installation.

SPWV
SPWV SPWV
SPWV Data Sheet Data Sheet (pdf)
SPWV Installation Instructions Installation Instructions (pdf)
SPWV Engineering Specs Engineering Specs
The SpectrAlert Advance SPWV is a white speaker for wall installation offering a high dB speaker.

SPRV
SPRV SPRV
SPRV Data Sheet Data Sheet (pdf)
SPRV Installation Instructions Installation Instructions (pdf)
SPRV Engineering Specs Engineering Specs
The SpectrAlert Advance SPRV is a red speaker for wall installation offering a high dB speaker .

SPSW
SPSW SPSW
SPSW Data Sheet Data Sheet (pdf)
SPSW Installation Instructions Installation Instructions (pdf)
SPSW Engineering Specs Engineering Specs
The SpectrAlert Advance SPSW is a white speaker strobe for wall installation with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SPSW-P
SPSW-P SPSW-P
SPSW-P Data Sheet Data Sheet (pdf)
SPSW-P Installation Instructions Installation Instructions (pdf)
SPSW-P Engineering Specs Engineering Specs
The SpectrAlert Advance SPSW-P is an umarked, white speaker strobe for wall installation with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT, or AGENT that can be manually applied to the product housing.

SPSRHK
SPSRHK SPSRHK
SPSRHK Data Sheet Data Sheet (pdf)
SPSRHK Installation Instructions Installation Instructions (pdf)
SPSRHK Engineering Specs Engineering Specs
The SpectrAlert Advance SPSRHK is a red, outdoor speaker strobe for wall installations with selectable strobe settings of 135, 150, 177, 185 cd.

SPSR
SPSR SPSR
SPSR Data Sheet Data Sheet (pdf)
SPSR Installation Instructions Installation Instructions (pdf)
SPSR Engineering Specs Engineering Specs
The SpectrAlert Advance SPSR is a red speaker strobe for wall installation with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SPSR-P
SPSR-P SPSR-P
SPSR-P Data Sheet Data Sheet (pdf)
SPSR-P Installation Instructions Installation Instructions (pdf)
SPSR-P Engineering Specs Engineering Specs
The SpectrAlert Advance SPSR-P is an umarked, red speaker strobe for wall installation with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT, or AGENT that can be manually applied to the product housing.

SPSWH
SPSWH SPSWH
SPSWH Data Sheet Data Sheet (pdf)
SPSWH Installation Instructions Installation Instructions (pdf)
SPSWH Engineering Specs Engineering Specs
The SpectrAlert Advance SPSWH is a white speaker strobe for wall installation with selectable strobe settings of 135, 150, 177 and 185 cd.

SPSWH-P
SPSWH-P SPSWH-P
SPSWH-P Data Sheet Data Sheet (pdf)
SPSWH-P Installation Instructions Installation Instructions (pdf)
SPSWH-P Engineering Specs Engineering Specs
The SpectrAlert Advance SPSWH-P is an unmarked, white speaker strobe for wall installation with selectable strobe settings of 135, 150, 177 and 185 cd. It includes a multi-alert label with FIRE, EVAC, ALERT, or AGENT that can be manually applied to the product housing.

SPSRH
SPSRH SPSRH
SPSRH Data Sheet Data Sheet (pdf)
SPSRH Installation Instructions Installation Instructions (pdf)
SPSRH Engineering Specs Engineering Specs
The SpectrAlert Advance SPSRH is a red speaker strobe for wall installation with selectable strobe settings of 135, 150, 177 and 185 cd.

SPSRK-P
SPSRK-P SPSRK-P
SPSRK-P Data Sheet Data Sheet (pdf)
SPSRK-P Installation Instructions Installation Instructions (pdf)
SPSRK-P Engineering Specs Engineering Specs
The SpectrAlert Advance SPSRK-P is an unmarked, red, outdoor speaker strobe for wall installation with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included. It includes a multi-alert label with FIRE, EVAC, ALERT, or AGENT that can be manually applied to the product housing.

SPSRH-P
SPSRH-P SPSRH-P
SPSRH-P Data Sheet Data Sheet (pdf)
SPSRH-P Installation Instructions Installation Instructions (pdf)
SPSRH-P Engineering Specs Engineering Specs
The SpectrAlert Advance SPSRH-P is an unmarked, red speaker strobe for wall installation with selectable strobe settings of 135, 150, 177 and 185 cd. It includes a multi-alert label with FIRE, EVAC, ALERT, or AGENT that can be manually applied to the product housing.

SPSWV
SPSWV SPSWV
SPSWV Data Sheet Data Sheet (pdf)
SPSWV Installation Instructions Installation Instructions (pdf)
SPSWV Engineering Specs Engineering Specs
The SpectrAlert Advance SPSWV is a white speaker strobe for wall installations with selectable strobe setting of 15, 15/75, 30, 75, 95, 110 and 115 cd, as well as a high dB speaker.

SPSWK-P
SPSWK-P SPSWK-P
SPSWK-P Data Sheet Data Sheet (pdf)
SPSWK-P Installation Instructions Installation Instructions (pdf)
SPSWK-P Engineering Specs Engineering Specs
The SpectrAlert Advance SPSWK-P is an unmarked, white, outdoor speaker strobe for wall installation with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included. It includes a multi-alert label with FIRE, EVAC, ALERT, or AGENT that can be manually applied to the product housing.

SPSWV-P
SPSWV-P SPSWV-P
SPSWV-P Data Sheet Data Sheet (pdf)
SPSWV-P Installation Instructions Installation Instructions (pdf)
SPSWV-P Engineering Specs Engineering Specs
The SpectrAlert Advance SPSWV-P is an umarked, white speaker strobe for wall installations with selectable strobe setting of 15, 15/75, 30, 75, 95, 110 and 115 cd, as well as a high dB speaker. It includes a multi-alert label with FIRE, EVAC, ALERT, or AGENT that can be manually applied to the product housing.

SPSRV
SPSRV SPSRV
SPSRV Data Sheet Data Sheet (pdf)
SPSRV Installation Instructions Installation Instructions (pdf)
SPSRV Engineering Specs Engineering Specs
The SpectrAlert Advance SPSRV is a red speaker strobe for wall installations with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd, as well as a high dB speaker.

SPSRV-P
SPSRV-P SPSRV-P
SPSRV-P Data Sheet Data Sheet (pdf)
SPSRV-P Installation Instructions Installation Instructions (pdf)
SPSRV-P Engineering Specs Engineering Specs
The SpectrAlert Advance SPSRV-P is an umarked, red speaker strobe for wall installations with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd, as well as a high dB speaker. It includes a multi-alert label with FIRE, EVAC, ALERT, or AGENT that can be manually applied to the product housing.

SPCW
SPCW SPCW
SPCW Data Sheet Data Sheet (pdf)
SPCW Installation Instructions Installation Instructions (pdf)
SPCW Engineering Specs Engineering Specs
The SpectrAlert Advance SPCW is a white speaker for ceiling installation.

SPCR
SPCR SPCR
SPCR Data Sheet Data Sheet (pdf)
SPCR Installation Instructions Installation Instructions (pdf)
SPCR Engineering Specs Engineering Specs
The SpectrAlert Advance SPCR is a red speaker for ceiling installation.

SPCWV
SPCWV SPCWV
SPCWV Data Sheet Data Sheet (pdf)
SPCWV Installation Instructions Installation Instructions (pdf)
SPCWV Engineering Specs Engineering Specs
The SpectrAlert Advance SPCWV is a white speaker for ceiling installation offering a high dB speaker.

SPCRV
SPCRV SPCRV
SPCRV Data Sheet Data Sheet (pdf)
SPCRV Installation Instructions Installation Instructions (pdf)
SPCRV Engineering Specs Engineering Specs
The SpectrAlert Advance SPCRV is a red speaker for ceiling installation offering a high dB speaker.

SPSCW
SPSCW SPSCW
SPSCW Data Sheet Data Sheet (pdf)
SPSCW Installation Instructions Installation Instructions (pdf)
SPSCW Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCW is a white speaker strobe for ceiling installations with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SPSCW-P
SPSCW-P SPSCW-P
SPSCW-P Data Sheet Data Sheet (pdf)
SPSCW-P Installation Instructions Installation Instructions (pdf)
SPSCW-P Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCW-P is an umarked, white speaker strobe for ceiling installations with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT, or AGENT that can be manually applied to the product housing.

SPSCR
SPSCR SPSCR
SPSCR Data Sheet Data Sheet (pdf)
SPSCR Installation Instructions Installation Instructions (pdf)
SPSCR Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCR is a red speaker strobe for ceiling installations with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SPSCWH
SPSCWH SPSCWH
SPSCWH Data Sheet Data Sheet (pdf)
SPSCWH Installation Instructions Installation Instructions (pdf)
SPSCWH Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCWH is a white speaker strobe for ceiling installations with selectable strobe settings of 135, 150, 177 and 185 cd.

SPSCWH-P
SPSCWH-P SPSCWH-P
SPSCWH-P Data Sheet Data Sheet (pdf)
SPSCWH-P Installation Instructions Installation Instructions (pdf)
SPSCWH-P Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCWH-P is an unmarked, white speaker strobe for ceiling installations with selectable strobe settings of 135, 150, 177 and 185 cd. It includes a multi-alert label with FIRE, EVAC, ALERT, or AGENT that can be manually applied to the product housing.

SPSCRH
SPSCRH SPSCRH
SPSCRH Data Sheet Data Sheet (pdf)
SPSCRH Installation Instructions Installation Instructions (pdf)
SPSCRH Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCRH is a red speaker strobe for ceiling installations with selectable strobe settings of 135, 150, 177 and 185 cd.

SPSCWV
SPSCWV SPSCWV
SPSCWV Data Sheet Data Sheet (pdf)
SPSCWV Installation Instructions Installation Instructions (pdf)
SPSCWV Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCWV is a white speaker strobe for ceiling installations with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd, as well as a high dB speaker.

SPSCRV
SPSCRV SPSCRV
SPSCRV Data Sheet Data Sheet (pdf)
SPSCRV Installation Instructions Installation Instructions (pdf)
SPSCRV Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCRV is a red speaker strobe for ceiling installations with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd, as well as a high dB speaker.

SPSCWVH
SPSCWVH SPSCWVH
SPSCWVH Data Sheet Data Sheet (pdf)
SPSCWVH Installation Instructions Installation Instructions (pdf)
SPSCWVH Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCWVH is a white speaker strobe for ceiling installations with selectable strobe settings of 135, 150, 177 and 185 cd, as well as a high dB speaker.

SPSCWVH-P
SPSCWVH-P SPSCWVH-P
SPSCWVH-P Data Sheet Data Sheet (pdf)
SPSCWVH-P Installation Instructions Installation Instructions (pdf)
SPSCWVH-P Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCWVH-P is an unmarked, white speaker strobe for ceiling installations with selectable strobe settings of 135, 150, 177 and 185 cd, as well as a high dB speaker. It includes a multi-alert label with FIRE, EVAC, ALERT, or AGENT that can be manually applied to the product housing.

SPSCRVH
SPSCRVH SPSCRVH
SPSCRVH Data Sheet Data Sheet (pdf)
SPSCRVH Installation Instructions Installation Instructions (pdf)
SPSCRVH Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCRVH is a red speaker strobe for ceiling installations with selectable strobe settings of 135, 150, 177 and 185 cd, as well as a high dB speaker.

RFPW
RFPW RFPW
RFPW Data Sheet Data Sheet (pdf)
The SpectrAlert Advance RFPW is a 9.5" x 7" white retrofit plate that covers the footprint of the legacy SpectrAlert wall-mount speaker strobe. Compatible with horn strobe & speaker strobe line.

RFP
RFP RFP
RFP Data Sheet Data Sheet (pdf)
The SpectrAlert Advance RFP is a 9.5" x 7" red retrofit plate that covers the footprint of the legacy SpectrAlert wall-mount speaker strobe. Compatible with horn strobe & speaker strobe line.

SPBBSCW
SPBBSCW SPBBSCW
SPBBSCW Data Sheet Data Sheet (pdf)
The SpectrAlert Advance SPBBSCW is a white ceiling mounted Back Box Skirt.

SPBBSC
SPBBSC SPBBSC
SPBBSC Data Sheet Data Sheet (pdf)
SPBBSC Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SPBBSC is a red ceiling mounted Back Box Skirt.

SPBBSW
SPBBSW SPBBSW
SPBBSW Data Sheet Data Sheet (pdf)
SPBBSW Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SPBBSW is a white wall mounted Back Box Skirt.

SPBBS
SPBBS SPBBS
SPBBS Data Sheet Data Sheet (pdf)
SPBBS Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance SPBBS is a red wall mounted Back Box Skirt.

TRW
TRW TRW
TRW Data Sheet Data Sheet (pdf)
TRW Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance TRW is a white wall mounted Trim Ring. Provides additional space in backbox.

TR
TR TR
TR Data Sheet Data Sheet (pdf)
TR Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance TR is a red wall mounted Trim Ring. Provides additional space in backbox.

TRCW
TRCW TRCW
TRCW Data Sheet Data Sheet (pdf)
TRCW Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance TRCW is a white ceiling mounted Trim Ring. Provides additional space in backbox.

TRC
TRC TRC
TRC Data Sheet Data Sheet (pdf)
TRC Installation Instructions Installation Instructions (pdf)
The SpectrAlert Advance TRC is a red ceiling mounted Trim Ring. Provides additional space in backbox.

SPWK
SPWK SPWK
SPWK Data Sheet Data Sheet (pdf)
SPWK Installation Instructions Installation Instructions (pdf)
SPWK Engineering Specs Engineering Specs
The SpectrAlert Advance SPWK is a white, outdoor speaker for wall installation.

WTP
WTP WTP
WTP Data Sheet Data Sheet (pdf)
WTP Installation Instructions Installation Instructions (pdf)
WTP Engineering Specs Engineering Specs
The SpectrAlert Advance WTP is a red mounting plate for flush mounting outdoor K series horns, strobes, and horn strobes. Especially for use with SpectrAlert Advance –R replacement outdoor models

WTPW
WTPW WTPW
WTPW Data Sheet Data Sheet (pdf)
WTPW Installation Instructions Installation Instructions (pdf)
WTPW Engineering Specs Engineering Specs
The SpectrAlert Advance WTP is a white mounting plate for flush mounting outdoor K series horns, strobes, and horn strobes. Especially for use with SpectrAlert Advance –R replacement outdoor models.

SPRK
SPRK SPRK
SPRK Data Sheet Data Sheet (pdf)
SPRK Installation Instructions Installation Instructions (pdf)
SPRK Engineering Specs Engineering Specs
The SpectrAlert Advance SPRK is a red, outdoor speaker for wall installation.

WTP-SP
WTP-SP WTP-SP
WTP-SP Data Sheet Data Sheet (pdf)
WTP-SP Installation Instructions Installation Instructions (pdf)
WTP-SP Engineering Specs Engineering Specs
The SpectrAlert Advance WTP is a red mounting plate for flush mounting outdoor K series speakers and speaker strobes. Especially for use with SpectrAlert Advance –R replacement outdoor models

WTP-SPW
WTP-SPW WTP-SPW
WTP-SPW Data Sheet Data Sheet (pdf)
WTP-SPW Installation Instructions Installation Instructions (pdf)
WTP-SPW Engineering Specs Engineering Specs
The SpectrAlert Advance WTP is a white mounting plate for flush mounting outdoor K series speakers and speaker strobes. Especially for use with SpectrAlert Advance –R replacement outdoor models.

SPSWK
SPSWK SPSWK
SPSWK Data Sheet Data Sheet (pdf)
SPSWK Installation Instructions Installation Instructions (pdf)
SPSWK Engineering Specs Engineering Specs
The SpectrAlert Advance SPSWK is a white, outdoor speaker strobe for wall installations with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SPSRK
SPSRK SPSRK
SPSRK Data Sheet Data Sheet (pdf)
SPSRK Installation Instructions Installation Instructions (pdf)
SPSRK Engineering Specs Engineering Specs
The SpectrAlert Advance SPSRK is a red, outdoor speaker strobe for wall installations with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SPCWK
SPCWK SPCWK
SPCWK Data Sheet Data Sheet (pdf)
SPCWK Installation Instructions Installation Instructions (pdf)
SPCWK Engineering Specs Engineering Specs
The SpectrAlert Advance SPCWK is a white, outdoor speaker for ceiling installation.

SPSCWK
SPSCWK SPSCWK
SPSCWK Data Sheet Data Sheet (pdf)
SPSCWK Installation Instructions Installation Instructions (pdf)
SPSCWK Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCWK is a white, outdoor speaker strobe for ceiling installations with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.

SPSCWHK
SPSCWHK SPSCWHK
SPSCWHK Data Sheet Data Sheet (pdf)
SPSCWHK Installation Instructions Installation Instructions (pdf)
SPSCWHK Engineering Specs Engineering Specs
The SpectrAlert Advance SPSCWHK is a white, outdoor speaker strobe for ceiling installations with selectable strobe settings of 135, 150, 177 and 185 cd.


Discontinued Products
Discontinued Model Installation Instructions Data Sheet Replacement Model
SPCWK-R SPCWK-R Brochure SPCWK-R Data Sheet
The SpectrAlert Advance SPCWK-R (replacement model) is a white, outdoor, ceiling-mount speaker. Offers mounting plate only – no back box included.
SPSCWHK-R SPSCWHK-R Brochure SPSCWHK-R Data Sheet
The SpectrAlert Advance SPSCWHK-R (replacement model) is a white, outdoor speaker strobe for ceiling installation with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Offers mounting plate only – no back box included.
SPSCWK-R SPSCWK-R Brochure SPSCWK-R Data Sheet
The SpectrAlert Advance SPSCWK-R (replacement model) is a white, outdoor speaker strobe for ceiling installation with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Offers mounting plate only – no back box included.
MP-2W-20BP    
The SpectrAlert Advance MP-2W-20BP is a bulk pack of 20 2-wire mounting plates.
MPK-2W-20BP    
The SpectrAlert Advance MPK-2W-20BP is a bulk pack of 20 2-wire, outdoor mounting plates.
P2RH-P P2RH-P Brochure P2RH-P Data Sheet P2RH
The SpectrAlert Advance P2RH-P is an unmarked, red, two-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.
P2RH-SP P2RH-SP Brochure P2RH-SP Data Sheet P2R-SP
Marked with "FUEGO," the SpectrAlert Advance P2RH-SP is a red, two-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
P4R-P P4R-P Brochure P4R-P Data Sheet P4R
The SpectrAlert Advance P4R-P is an unmarked, red, four-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.
P4RH-P P4RH-P Brochure P4RH-P Data Sheet P4RH
The SpectrAlert Advance P4RH-P is an unmarked, red, four-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.
P4RHK P4RHK Brochure P4RHK Data Sheet P4RK
The SpectrAlert Advance P4RHK is a red, four-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
P4RHK-R P4RHK-R Brochure P4RHK-R Data Sheet P4RK
The SpectrAlert Advance P4RHK-R (replacement model) is a red, four-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Offers mounting plate only - no back box included.
P4WH P4WH Brochure P4WH Data Sheet P4W
The SpectrAlert Advance P4WH is a white, four-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
P4WH-P P4WH-P Brochure P4WH-P Data Sheet P4WH
The SpectrAlert Advance P4WH-P is an unmarked, white, four-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.
PC2RH-P PC2RH-P Brochure PC2RH-P Data Sheet PC2RH
The SpectrAlert Advance PC2RH-P is an unmarked, red, two-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.
PC2RK-R PC2RK-R Brochure PC2RK-R Data Sheet
The SpectrAlert Advance PC2RK-R (replacement model) is a red, two-wire, ceiling-mount, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Offers mounting plate only - no back box included.
PC2RHK-R PC2RHK-R Brochure PC2RHK-R Data Sheet
The SpectrAlert Advance PC2RHK-R (replacement model) is a red, two-wire, ceiling-mount, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Offers mounting plate only - no back box included.
PC2WH-SP PC2WH-SP Brochure PC2WH-SP Data Sheet PC2W
Marked with "FUEGO," the SpectrAlert Advance PC2WH-SP is a white, two-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
PC4RK PC4RK Brochure PC4RK Data Sheet PC4R
The SpectrAlert Advance PC4RK is a red, four-wire, ceiling-mount, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
PC4RK-R PC4RK-R Brochure PC4RK-R Data Sheet PC4R
The SpectrAlert Advance PC4RK-R (replacement model) is a red, four-wire, ceiling-mount, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Offers mounting plate only - no back box included.
PC4RHK PC4RHK Brochure PC4RHK Data Sheet PC4R
The SpectrAlert Advance PC4RHK is a red, four-wire, ceiling-mount, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.
PC4RHK-R PC4RHK-R Brochure PC4RHK-R Data Sheet PC4R
The SpectrAlert Advance PC4RHK-R (replacement model) is a red, four-wire, ceiling-mount, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177, and 185 cd. Offers mounting plate only - no back box included.
SCR-P SCR-P Brochure SCR-P Data Sheet SCR
The SpectrAlert Advance SCR-P is an unmarked, red, ceiling-mount strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.
SCRH-P SCRH-P Brochure SCRH-P Data Sheet SCRH
The SpectrAlert Advance SCRH-P is an unmarked, red, ceiling-mount strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.
SCRHK-R SCRHK-R Brochure SCRHK-R Data Sheet
The SpectrAlert Advance SCRHK-R (replacement model) is a red, ceiling-mount, outdoor strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Offers mounting plate only - no back box included.
SCRK-R SCRK-R Brochure SCRK-R Data Sheet
The SpectrAlert Advance SCRK-R (replacement model) is a red, ceiling-mount, outdoor strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Offers mounting plate only - no back box included.
SCW-SP SCW-SP Brochure SCW-SP Data Sheet SCW
Marked with "FUEGO," the SpectrAlert Advance SCW-SP is a white, ceiling-mount strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
SCWH-P SCWH-P Brochure SCWH-P Data Sheet SCWH
The SpectrAlert Advance SCWH-P is an unmarked, white, ceiling-mount strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. It includes a multi-alert label with FIRE, EVAC, ALERT or AGENT that can be manually applied to the product housing.
SCWH-SP SCWH-SP Brochure SCWH-SP Data Sheet SCWH
Marked with "FUEGO," the SpectrAlert Advance SCWH-SP is a white, ceiling-mount strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
SRH-SP SRH-SP Brochure SRH-SP Data Sheet SRH
Marked with "FUEGO," the SpectrAlert Advance SRH-SP is a red strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
PC4WH PC4WH Brochure PC4WH Data Sheet PC4W
The SpectrAlert Advance PC4WH is a white, four-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.