Conventional Detection Product Line
i3 Series100 Series 400 SeriesHeat DetectorsBeam Detectors
2-Wire CompatibilityMulti-Voltage RelaysBasesAccessoriesCarbon MonoxideAspiration

Conventional Detection
Search for: 100

8100
8100 8100
8100 Data Sheet Data Sheet (pdf)
8100 Engineering Specs Engineering Specs
Conventional FAAST aspirating smoke detector

RA100Z
RA100Z RA100Z
RA100Z Data Sheet Data Sheet (pdf)
RA100Z Installation Instructions Installation Instructions (pdf)
RA100Z remote annunciator is designed for both conventional and intelligent applications.

2151
2151 2151
2151 Data Sheet Data Sheet (pdf)
2151 Installation Instructions Installation Instructions (pdf)
The 2151 is a low profile, plug-in photoelectric smoke detector.

B110LP
B110LP B110LP
B110LP Installation Instructions Installation Instructions (pdf)
The B110LP is a 2-wire base for use with 100 Series smoke detectors.

B110RLP
B110RLP B110RLP
B110RLP Installation Instructions Installation Instructions (pdf)
B110RLP is a 2-wire base for use with 100 Series smoke detectors.

B112LP
B112LP B112LP
B112LP Installation Instructions Installation Instructions (pdf)
The B112LP is a 4-wire base with Form A&C relay contacts, for use with 100 Series smoke detectors.

B114LP
B114LP B114LP
B114LP Installation Instructions Installation Instructions (pdf)
The B114LP is a 4-wire base with Form A&C and Form A Supervisory relay contacts, for use with 100 Series smoke detectors.

B116LP
B116LP B116LP
B116LP Installation Instructions Installation Instructions (pdf)
The B116LP is a 2-wire base with a Form C relay contact, for use with 100 Series Smoke detectors.

MOD400R
MOD400R MOD400R
MOD400R Data Sheet Data Sheet (pdf)
MOD400R Installation Instructions Installation Instructions (pdf)
The MOD400R is used to check the sensitivity of System Sensor 100, 200, 400, and 500 Series smoke detectors, and DH100, DH200, DH400, and DH500 Series duct smoke detectors.

RMK400
RMK400 RMK400
RMK400 Data Sheet Data Sheet (pdf)
RMK400 Installation Instructions Installation Instructions (pdf)
The RMK400 Recessed Mounting Kit is for use with System Sensor 100, 200, 400, and 500 Series plug-in detectors.

XR2
XR2 XR2
XR2 Installation Instructions Installation Instructions (pdf)
The XR2 is an installation/removal tool for use with previous models of the 100 and 200 series plug-in smoke detectors.
Detector removal tool guide

2012H
2012H 2012H
2012H Data Sheet Data Sheet (pdf)
2012H Installation Instructions Installation Instructions (pdf)
The 2012H is a direct-wire smoke detector with built-in relay and horn, manufactured by System Sensor China and available from our distributors in Canada and Australia.

2151T
2151T 2151T
2151T Installation Instructions Installation Instructions (pdf)
The 2151T is a low profile, plug-in photoelectric smoke detector with fixed-temperature heat sensor.


Discontinued Products
Discontinued Model Installation Instructions Data Sheet Replacement Model
2100TR 2100TR Brochure 2100TR Data Sheet 2WTR-B
The 2100TR is a low profile, 2-wire, photoelectric smoke detector with a 135°F thermal sensor.
2112/24R 2112/24R Brochure 2112/24R Data Sheet 4WTR-B
The 2112/24R is a low profile, 4-wire, photoelectric smoke detector with an auxiliary Form C relay.
2112/24TR 2112/24TR Brochure 2112/24TR Data Sheet 4WTR-B
The 2112/24TR is a low profile, 4-wire, photoelectric smoke detector with a 135°F thermal sensor and auxiliary Form C relay.
2100AT 2100AT Brochure 2100AT Data Sheet 2WTA-B
The 2100AT is a low profile, 2-wire, photoelectric smoke detector with a built-in sounder.
2112/24AT 2112/24AT Brochure 2112/24AT Data Sheet 4WTA-B
The 2112/24AT is a low profile, 4-wire, photoelectric smoke detector with a 135°F thermal sensor and built-in sounder.
2112/24ATR 2112/24ATR Brochure 2112/24ATR Data Sheet 4WTAR-B
The 2112/24ATR is a low profile, 4-wire, photoelectric smoke detector with a 135°F thermal sensor, built-in sounder, and auxiliary Form C relay.
2112/24AITR 2112/24AITR Brochure 2112/24AITR Data Sheet 4WITAR-B
The 2112/24AITR is a low profile, 4-wire, photoelectric smoke detector with an isolated 135°F thermal sensor, built-in sounder, and auxiliary Form C relay.
1151 1151 Brochure 1151 Data Sheet 2W-B
The 1151 is a low profile, plug-in ionization smoke detector.
2100S 2100S Brochure 2100S Data Sheet 2W-B

2100TS 2100TS Brochure 2100TS Data Sheet 2WT-B

2112/24S 2112/24S Brochure 2112/24S Data Sheet 4W-B

2112/24TS 2112/24TS Brochure 2112/24TS Data Sheet 4WT-B

2100 2100 Brochure   2W-B

2100T 2100T Brochure   2WT-B

2100D 2100D Brochure   2W-B

2100TD 2100TD Brochure   2WT-B

2112/24B 2112/24B Brochure   4W-B

2112/24TB 2112/24TB Brochure   4WT-B

2112/24TSRB 2112/24TSRB Brochure   4WTR-B

2112/24D 2112/24D Brochure   4W-B

2112/24TD 2112/24TD Brochure   4WT-B