<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>LifeSafety Magazine &#187; Winter 2005</title>
	<atom:link href="http://www.systemsensor.com/lifesafety/category/winter-2005/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.systemsensor.com/lifesafety</link>
	<description>quarterly information from the leader in notification and detection</description>
	<lastBuildDate>Tue, 24 Jan 2012 16:39:41 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
		<item>
		<title>Editorial: We are Life Safety</title>
		<link>http://www.systemsensor.com/lifesafety/2009/11/editorial-we-are-life-safety/</link>
		<comments>http://www.systemsensor.com/lifesafety/2009/11/editorial-we-are-life-safety/#comments</comments>
		<pubDate>Thu, 12 Nov 2009 18:31:32 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Editorial]]></category>
		<category><![CDATA[Winter 2005]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1539</guid>
		<description><![CDATA[Today’s fire systems play a crucial role in alerting people to a potential threat. I heard a fire chief give a presentation to installers at a life-safety conference once. He said, “The truth is, you guys do the job for me. A fire erupts, we roll the trucks, get to the scene and usually everyone [...]]]></description>
			<content:encoded><![CDATA[<p>Today’s fire systems play a crucial role in alerting people to a potential threat. I heard a fire chief give a presentation to installers at a life-safety conference once. He said, “The truth is, you guys do the job for me. A fire erupts, we roll the trucks, get to the scene and usually everyone is already out of the building. I get interviewed and congratulated by the press, and all I did was fight the fire. You guys protected their lives.”</p>
<p>Since 9/11, Honeywell companies all over the world have been joining forces to raise money for various catastrophes. Honeywell has already committed $500,000 in response to Hurricane Katrina, as well as a dollar-for-dollar match to all employee personal donations. Our employees have been extremely giving, already pledging more than $550,000.</p>
<p>Of course, System Sensor is always innovating ideas and solutions. Any time we learn of a fire or tragedy where lives were lost, our engineers are researching, testing and implementing preventative solutions. Historically, smoke detectors were capable of detecting smoke and making a noise. That was it. Today, we have control panels that distinguish between devices and communicate highly detailed information about the threat. We also have intelligent systems that process detailed, analog data from detectors about smoke levels.</p>
<p>We are not just in the fire detection business anymore. We are in life safety.</p>
<p>John W. Hakanson</p>
<p>President<br />
System Sensor</p>
<p><a class="a2a_dd a2a_target addtoany_share_save" href="http://www.addtoany.com/share_save#url=http%3A%2F%2Fwww.systemsensor.com%2Flifesafety%2F2009%2F11%2Feditorial-we-are-life-safety%2F&amp;title=Editorial%3A%20We%20are%20Life%20Safety" id="wpa2a_2"><img src="http://www.systemsensor.com/lifesafety/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="Share"/></a></p>]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/lifesafety/2009/11/editorial-we-are-life-safety/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Cover: Code, Training and Equipment: All Vital to Healthcare Fire and Life Safety</title>
		<link>http://www.systemsensor.com/lifesafety/2009/11/cover-code-training-and-equipment-all-vital-to-healthcare-fire-and-life-safety/</link>
		<comments>http://www.systemsensor.com/lifesafety/2009/11/cover-code-training-and-equipment-all-vital-to-healthcare-fire-and-life-safety/#comments</comments>
		<pubDate>Thu, 12 Nov 2009 18:31:28 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Audible/Visible Notification]]></category>
		<category><![CDATA[Cover Features]]></category>
		<category><![CDATA[Healthcare]]></category>
		<category><![CDATA[Intelligent Detection]]></category>
		<category><![CDATA[Winter 2005]]></category>
		<category><![CDATA[Carbon monoxide]]></category>
		<category><![CDATA[Smoke detection]]></category>
		<category><![CDATA[Speakers and Strobes]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1541</guid>
		<description><![CDATA[An interview with Barnes-Jewish Hospital’s manager of plant operations. Mike Menzel, manager of plant operations for Barnes-Jewish Hospital in St. Louis, attributes the safety of patients and staff to a strict adherence to fire-protection codes, by-the-book installations and a commitment to maintenance and training. Menzel oversees 6.5 million square feet of space at Barnes-Jewish Hospital, [...]]]></description>
			<content:encoded><![CDATA[<p><em>An interview with Barnes-Jewish Hospital’s manager of plant operations.</em></p>
<p>Mike Menzel, manager of plant operations for Barnes-Jewish Hospital in St. Louis, attributes the safety of patients and staff to a strict adherence to fire-protection codes, by-the-book installations and a commitment to maintenance and training.</p>
<p>Menzel oversees 6.5 million square feet of space at Barnes-Jewish Hospital, one of the most celebrated healthcare facilities in the world.</p>
<p>With continual testing of equipment and repeated practice by the entire hospital staff, Menzel and his crew are able to provide a safe and secure facility where physicians and researchers can concentrate on developing other types of life-saving techniques.</p>
<p>“Through our insurance company, we developed a system that adheres to NFPA 25 standards,” says Menzel. “We test every flow switch quarterly and inspect all the valves monthly. On the fire alarm system, we adhere to NFPA 72.”</p>
<p>Although Menzel conforms to NFPA 25 and 72, two of the most common standards for ensuring life safety, it’s the scale of his operation that stands out. “We do all of our own maintenance,” says Menzel. “I have two electricians and two plumbers in charge of that. They spend about three weeks out of a month just doing maintenance and testing. The other week of the month is usually taken up by fire marshal inspections, shut downs and other contractor requests.”</p>
<p><strong>Fire Drills Every Day</strong></p>
<p>Menzel attributes Barnes-Jewish Hospital’s exemplary safety record to all staff members. “We have more than 400 fire drills every year. Every quarter, for every shift, we have a drill for each of the patient divisions,” he says. “So that means you have two shifts a day multiplied by 50 patient divisions. Then you figure in the ambulatory-care buildings that we drill four times each year. Plus, all the business groups are drilled annually.”</p>
<p>Menzel realizes that unwarranted fire alarms weaken the hospital’s rigid training regimen. To ward off apathy toward what could be perceived as invasive treatment, he uses the element of surprise. “Half of the drills are announced. They know ahead of time that we are having a drill,” he says. “But the other half is unannounced, so the staff is used to responding like there is a real fire. That’s what we need to happen. We had an issue many years ago where people were ignoring the fire alarm system because we were having problems with the bells going off due to the amount of tie-ins wehad. People were becoming immune to it.”</p>
<p>To gain more control over the system, a concerted effort was made to reduce the amount of false alarms. This, in turn, made people more accountable for the real alarms. “We put tighter reigns on the contractors because you can’t have the fire department come out three times a night because the alarm system is going off. The cost is $600 each time they come out,” says Menzel. “We also have modified our hot work-permit system because there were some problems with the way we were reporting work on the system and who it was being reported to. We now have control over the process. We put the detection system into silent mode for the area that is being worked on and monitor any alarm.”</p>
<p>Along with the plant operations team, there are several others involved in this campus-wide effort. “The hospital put together a team of 10 people from security, facility engineering and safety for the fire drills,” Menzel explains. “We are now set up so that we talk to each other when there will be work on the system. The security department manages the monitoring about four blocks from here because we’re mandated to have offsite monitoring of our system. All of our buildings’ systems report to that location.”</p>
<p><strong>A Century of Progress</strong></p>
<p>“We will be 98 percent sprinkled as of the end of 2006,”Menzel reports. However, getting to this point was not an easy task. “On the Barnes-Jewish campus, we have buildings with construction dates that range from the early 1900s to our newest one that was opened in 2004.</p>
<p>“The real issue you face is renovated over the years,” explains Menzel.</p>
<p>With each new nurse call system or additional lighting, the wire starts to mount up in the ceiling, and eventually becomes jumbled. This mess of wire makes the installation of sprinkler systems tedious.</p>
<p>“When we decided to renovate different areas of the hospital, we bit the bullet and have been dealing with the wiring issue. We are taking the time to put everything into trays, labeling them and cleaning it up.”</p>
<p>The decision to go forward with sprinkling the entire facility was a monumental step to ensure occupant safety. As with any major spending project, the decision required backing from the highest levels of administration. “You do need the support to make these projects happen,” says Menzel.</p>
<p>The hospital’s safety focus spawned an Interior Review Committee that must check all hospital materials for flammability. “We don’t let just any material in the hospital,” Menzel says. “Your carpeting, drapes and such are flame when buildings are partially retardant, even the furniture in the room. We use metals and materials that won’t catch on fire. A lot of thought goes into this to make sure we are providing a safe environment. Even the closets are all sprinkled because of the linens. Sprinklers and smoke detection in every patient room is critical.”</p>
<p><strong>In the Event of Fire</strong></p>
<p>“If we have a fire somewhere, we do not evacuate the building. We move horizontally through the building,” says Menzel. “To move people in a high-rise, especially sick people, is difficult. Most occupants are unable to help themselves, so our focus is on creating safe zones for them to go to in the event of a fire. But that means we have to be careful of what we do when we change the configuration of the building.”</p>
<p>Equally as important as the layout of the building is the plan that goes into action once an alarm sounds. “If you have a smoke detector alarm going off and then the suppression system kicks in, now you know you have an actual fire,” says Menzel. “Then, if you have more smoke detectors go off nearby, you know it’s spreading. There’s a whole philosophy that goes on in the hospital. You really depend on the systems you put in place to take care of the people. Human intervention and common sense are a big part of the life-safety system.”</p>
<p> </p>
<p>[sidebar]</p>
<p>The RACE System</p>
<p>Mike Menzel, manager of plant operations, attests to the effectiveness of Barnes-Jewish Hospital’s RACE Program, which stands for Remove, Activate, Contain and Extinguish.</p>
<p>“We had an incident last New Year’s Eve,” Menzel says. “This happened around midnight, and there were maybe four people working on the floor. A patient was admitted and that person was put on oxygen, but managed to conceal a pack of cigarettes and a lighter. The patient proceeded to light up a cigarette in the room, and you can imagine what happened with the oxygen. It started on fire. Well, the        patient rang the bell right away and our patient-care tech knew from our drills that he had to disconnect the oxygen immediately. The fire was contained, the patient was not seriously injured and building damage was minimal.</p>
<p>“My point is, when the alarm went off, the nursing staff reacted right away. They went around and closed the doors and made sure everything was secure and waited for the next instruction. That’s why we drill 400 times a year. They can perform when needed to.”</p>
<p>The patient-care technician followed the steps in the RACE program, and the result was minor patient injury and minimal building damage.</p>
<p><a class="a2a_dd a2a_target addtoany_share_save" href="http://www.addtoany.com/share_save#url=http%3A%2F%2Fwww.systemsensor.com%2Flifesafety%2F2009%2F11%2Fcover-code-training-and-equipment-all-vital-to-healthcare-fire-and-life-safety%2F&amp;title=Cover%3A%20Code%2C%20Training%20and%20Equipment%3A%20All%20Vital%20to%20Healthcare%20Fire%20and%20Life%20Safety" id="wpa2a_4"><img src="http://www.systemsensor.com/lifesafety/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="Share"/></a></p>]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/lifesafety/2009/11/cover-code-training-and-equipment-all-vital-to-healthcare-fire-and-life-safety/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Guidelines: Communication Is Imperative for Duct Smoke-Detector Installations</title>
		<link>http://www.systemsensor.com/lifesafety/2009/11/guidelines-communication-is-imperative-for-duct-smoke-detector-installations/</link>
		<comments>http://www.systemsensor.com/lifesafety/2009/11/guidelines-communication-is-imperative-for-duct-smoke-detector-installations/#comments</comments>
		<pubDate>Thu, 12 Nov 2009 18:31:25 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Guidelines]]></category>
		<category><![CDATA[HVAC Monitoring]]></category>
		<category><![CDATA[Winter 2005]]></category>
		<category><![CDATA[HVAC]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1543</guid>
		<description><![CDATA[Craftsmen must coordinate efforts to properly install detectors. The proper installation of duct smoke detectors is critical to preventing the transfer of smoke and other toxic gases during a fire. Unlike standard smoke detectors that are set up by a single installer, heating/ventilation/air conditioning (HVAC)-contaminant monitors can be set up by installers of various trades, [...]]]></description>
			<content:encoded><![CDATA[<p><em>Craftsmen must coordinate efforts to properly install detectors.</em></p>
<p>The proper installation of duct smoke detectors is critical to preventing the transfer of smoke and other toxic gases during a fire. Unlike standard smoke detectors that are set up by a single installer, heating/ventilation/air conditioning (HVAC)-contaminant monitors can be set up by installers of various trades, making communication imperative.</p>
<p>Installers of at least four crafts may be involved in a duct smoke-detector installation, including an air conditioning or roof top unit (RTU) installer; a mechanical contractor responsible for duct work; an electrician for handling high-voltage wiring and conduit; and a technician who installs the building control panel.</p>
<p>“Traditionally, it goes by union guidelines,” says Chuck Harding, general manager and founder of Harding Heating in Schaumburg, Ill. “Sheet metal workers do the duct work. So, they connect the smoke detector to the HVAC system. The electricians then provide the power. Those are the traditional jurisdiction lines that are pretty much defined throughout the country, as far as the unions are concerned.”</p>
<p>However, Harding has seen jobs during 20 years of running his own business that were not as traditional. “I’ve also seen each one of the crafts do the entire job by themselves. It just depends on who is on the job. You can’t always assume that all the crafts are involved. If it is a smaller job, it’s not uncommon for the HVAC guy to do it all.”</p>
<p><strong>Which Code Authorities Prevail?</strong></p>
<p>The importance of top-down communication can also be critical in making sure a job follows the strict body of laws that govern it. But, sometimes the installers are unaware of which code prevails: national or local. Therefore, communicating the certified code of the Authority Having Jurisdiction (AHJ) is a critical first step for every installer.</p>
<p>For example, installation may be originated by the ductwork installer or the RTU installer. However, if the voltage to power the detector is 120 VAC, in accordance to the National Electrical Code, an electrician must install the conduit and run the wire. Who, then, is responsible for connecting the RTU to the auxiliary relays for shutdown during a fire?</p>
<p>“Fortunately, in larger jobs, this is normally written in the specification,” explains Harding. “The engineer’s orders tell you who is the authority having jurisdiction. These are written commonly in a way that identifies such-and-such trade will provide ‘X’ service, while another provides different service. A lot of it depends on the detector; some are high voltage, some are low voltage. Again, it all comes back to the engineer’s order, but I have seen it where the owner dictates this. Some dictate a lot on a job.”</p>
<p>Knowing who the AHJ is, therefore, must be relayed to the installers for each job. Companies like Harding Heating, which take on jobs in Illinois, Wisconsin and Indiana, have to be aware of the many different codes that may be applicable.</p>
<p>“It’s village-to-village and depends on the authority having jurisdiction,” says Harding. “Some villages have more emphasis on some things than others do. For duct smoke detectors in particular, the Building Officials and Code Administrators code says they must be installed in buildings that have 2,000 cubic feet of airflow per minute. But, some village codes exceed this; some don’t. Just like some have remote testing requirements and others don’t. It makes communication very important.”</p>
<p>Another code-adherence tip Harding offers is to make sure the duct smoke detector’s installation paperwork is handed down the line to the craftsmen who will handle the final phases of installation, as is required by national code. “Passing off the installation manual is a must. We leave it in the detector,” says Harding. “But, somewhere down the line, someone takes it or does not think to leave it for the next guy. It’s not intentional, but it is a violation of the code.”</p>
<p><strong>Start-up and Maintenance </strong></p>
<p>System Sensor smoke detectors are designed to be as maintenance-free as possible. However, due to the environment they are in, dust, dirt and other foreign matter can accumulate inside detectors, changing the level of sensitivity. This is especially true with duct smoke detectors. More sensitivity results in unwanted alarms. Less sensitivity results in reduced protection. Both cases are undesirable. Detectors should be tested periodically and maintained at regular intervals (see “Typical Testing Procedures for Duct-Type Smoke Detectors”).</p>
<p>“I always tell my customers to follow a stringent testing program,” says Harding. “Of course, they work the first day, but what about three years down the road? You have to follow the maintenance procedures set out by the manufacturer, as well as the code. Remember, the building code is there for a purpose: It is the minimum for safety. It is not to be violated or ignored for installation or maintenance.”</p>
<p><a class="a2a_dd a2a_target addtoany_share_save" href="http://www.addtoany.com/share_save#url=http%3A%2F%2Fwww.systemsensor.com%2Flifesafety%2F2009%2F11%2Fguidelines-communication-is-imperative-for-duct-smoke-detector-installations%2F&amp;title=Guidelines%3A%20Communication%20Is%20Imperative%20for%20Duct%20Smoke-Detector%20Installations" id="wpa2a_6"><img src="http://www.systemsensor.com/lifesafety/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="Share"/></a></p>]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/lifesafety/2009/11/guidelines-communication-is-imperative-for-duct-smoke-detector-installations/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Typical Testing Procedures for Duct-Type Smoke Detectors</title>
		<link>http://www.systemsensor.com/lifesafety/2009/11/typical-testing-procedures-for-duct-type-smoke-detectors/</link>
		<comments>http://www.systemsensor.com/lifesafety/2009/11/typical-testing-procedures-for-duct-type-smoke-detectors/#comments</comments>
		<pubDate>Thu, 12 Nov 2009 18:31:22 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Guidelines]]></category>
		<category><![CDATA[HVAC Monitoring]]></category>
		<category><![CDATA[Winter 2005]]></category>
		<category><![CDATA[HVAC]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1545</guid>
		<description><![CDATA[A manufacturer’s specific recommended practices must be followed when testing duct-type smoke detectors (refer to NFPA Standard 90A, Section 6.4, 2002 Edition, and NFPA Standard 72, Chapter 10, 2002 Edition). In general, all smoke detectors should be tested or inspected at least annually. This will ensure the detectors are sampling the air stream, are operative [...]]]></description>
			<content:encoded><![CDATA[<p>A manufacturer’s specific recommended practices must be followed when testing duct-type smoke detectors (refer to NFPA Standard 90A, Section 6.4, 2002 Edition, and NFPA Standard 72, Chapter 10, 2002 Edition).</p>
<p>In general, all smoke detectors should be tested or inspected at least annually. This will ensure the detectors are sampling the air stream, are operative and are producing the intended response.</p>
<p>Duct fires should not be used to test duct smoke detectors. This procedure does not provide a consistent, measurable method of determining if the detectors are performing properly. The test procedures and test equipment recommended by the detector’s manufacturer are the best way to test these detectors.</p>
<p>Most detectors are equipped with a built-in test mechanism, electronic metering equipment or aerosol test apparatus (refer to manufacturer’s specifications for details). However, you still have to notify the proper authorities, including those who would automatically receive a real fire alarm signal, to prevent unnecessary responses.</p>
<p>Always restore the zone or system at the completion of the testing. Then, notify all the people contacted at the beginning of the test and let them know that testing has been completed and the system is operational.</p>
<p><a class="a2a_dd a2a_target addtoany_share_save" href="http://www.addtoany.com/share_save#url=http%3A%2F%2Fwww.systemsensor.com%2Flifesafety%2F2009%2F11%2Ftypical-testing-procedures-for-duct-type-smoke-detectors%2F&amp;title=Typical%20Testing%20Procedures%20for%20Duct-Type%20Smoke%20Detectors" id="wpa2a_8"><img src="http://www.systemsensor.com/lifesafety/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="Share"/></a></p>]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/lifesafety/2009/11/typical-testing-procedures-for-duct-type-smoke-detectors/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Application Documents</title>
		<link>http://www.systemsensor.com/lifesafety/2009/11/application-documents/</link>
		<comments>http://www.systemsensor.com/lifesafety/2009/11/application-documents/#comments</comments>
		<pubDate>Thu, 12 Nov 2009 18:31:19 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Guidelines]]></category>
		<category><![CDATA[HVAC Monitoring]]></category>
		<category><![CDATA[Winter 2005]]></category>
		<category><![CDATA[HVAC]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1547</guid>
		<description><![CDATA[There are several important documents that provide guidance concerning the performance, application and installation of duct smoke detectors: 1. U.L. Standard 268A, Standard for Smoke Detectors for Duct Applications 2. NFPA Standard 90A, Section 6.4 (2002 Edition), Installation of Air Conditioning and Ventilating Systems 3. NFPA 92A, Recommended Practice for Smoke Control Systems 4. NFPA [...]]]></description>
			<content:encoded><![CDATA[<p>There are several important documents that provide guidance concerning the performance, application and installation of duct smoke detectors:</p>
<p>1. U.L. Standard 268A, Standard for Smoke Detectors for Duct Applications</p>
<p>2. NFPA Standard 90A, Section 6.4 (2002 Edition), Installation of Air Conditioning and Ventilating Systems</p>
<p>3. NFPA 92A, Recommended Practice for Smoke Control Systems</p>
<p>4. NFPA Standard 72, Chapter 10 (2002 Edition), National Fire Alarm Code</p>
<p>5. NFPA Standard 101, Life Safety Code</p>
<p>6. ASHRAE Handbook and Product Directory, “Fire and Smoke Control”</p>
<p><a class="a2a_dd a2a_target addtoany_share_save" href="http://www.addtoany.com/share_save#url=http%3A%2F%2Fwww.systemsensor.com%2Flifesafety%2F2009%2F11%2Fapplication-documents%2F&amp;title=Application%20Documents" id="wpa2a_10"><img src="http://www.systemsensor.com/lifesafety/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="Share"/></a></p>]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/lifesafety/2009/11/application-documents/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Product: Intelligent Smoke Detectors for Critical Applications</title>
		<link>http://www.systemsensor.com/lifesafety/2009/11/product-intelligent-smoke-detectors-for-critical-applications/</link>
		<comments>http://www.systemsensor.com/lifesafety/2009/11/product-intelligent-smoke-detectors-for-critical-applications/#comments</comments>
		<pubDate>Thu, 12 Nov 2009 18:31:16 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Intelligent Detection]]></category>
		<category><![CDATA[Winter 2005]]></category>
		<category><![CDATA[Smoke detection]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1549</guid>
		<description><![CDATA[Ultra-sensitive laser-based technology protects electronic equipment. Fire and smoke not only endanger lives, they can also cause varying degrees of damage to any type of facility. In a high-tech facility, such as a hospital, even a small fire can be devastating to its operation. Electronic equipment is particularly vulnerable to smoke, much more so than [...]]]></description>
			<content:encoded><![CDATA[<p><em>Ultra-sensitive laser-based technology protects electronic equipment.</em></p>
<p>Fire and smoke not only endanger lives, they can also cause varying degrees of damage to any type of facility. In a high-tech facility, such as a hospital, even a small fire can be devastating to its operation.</p>
<p>Electronic equipment is particularly vulnerable to smoke, much more so than heat. In many cases, the fire is contained to a small physical area and extinguished relatively quickly, but the entire facility is still negatively affected by the smoke.</p>
<p>For example, smoke in telecommunications facilities can disrupt service for up to several weeks, cause major disruptions in telephone communications and cause costly damage to equipment, even when the fire is promptly controlled. In critical applications, such as telecommunications switching stations, computer rooms, clean rooms, hospitals, museums, archives and historic buildings, installing the highest sensitivity spot-type smoke detectors is the best bet for protection against damage to electronic equipment.</p>
<p>Intelligent microprocessor-controlled smoke detectors that incorporate laser-based technology, such as System Sensor’s laser detector, are able to pinpoint the exact locations of a fire by identifying the address of the detector sensing the smoke. This can greatly reduce response time in real fire situations because smoke at such low levels is not visible to the human eye.</p>
<p>Ideal for critical applications, System Sensor&#8217;s laser detector is capable of sensing the presence of smoke and triggering an alarm up to 20 minutes earlier than standard photoelectric smoke detectors. While this type of ultrasensitive detector works on the same light-scattering principle as standard photoelectric detectors, System Sensor’s laser detector operates with sensitivity levels 100 times greater.</p>
<p>Using an extremely bright, controlled laser diode, the laser beam is transmitted through the chamber to a light trap to eliminate any reflection. If a particle of smoke enters the chamber, light from the laser is scattered.</p>
<p>System Sensor’s laser detector then uses its patented on-board algorithms to check the nature of the scattered light and determine if smoke is actually present. If smoke is positively confirmed, the alarm signals. The algorithms, which include multi-stage drift compensation, internal self-diagnostics and transient signal rejection algorithms, help prevent nuisance and false alarms, even when set to  extremely high sensitivity.</p>
<p><strong>Laser Detector vs. Aspirating Systems</strong></p>
<p>Traditionally, the only way to achieve highly sensitive smoke detection was through the use of aspirating smoke-detection systems. Aspirating systems operate by drawing air and smoke through a network of pipe, or tubing, which is then routed throughout the protected space. By their nature, these types of systems are subject to the effects of dilution.</p>
<p>During an actual fire, smoke is drawn into the aspirating system’s pipe through one of its sampling ports. At the same time, the system’s other sampling ports may continue to draw clean air into the pipe from areas that the smoke has not yet reached. As a result, the sensitivity level in an aspirating system’s smoke sensor must be set much higher to offset the effects of dilution.</p>
<p>In critical applications that require very early warning detection, you can use either an aspirating system or a detector like System Sensor’s laser model. If the building already has a fire alarm control panel, or if one will be installed, System Sensor’s laser detector will be more cost effective for several reasons. For one, System Sensor’s laser detector will be installed on the same pair of wires as the other detectors that have been installed. Also, the company that installs the fire alarm control panel will install, service and maintain these detectors too.</p>
<p>Laser-based spot-type detectors, such as System Sensor’s Pinnacle™ or Notifier’s View, are not subject to dilution. In fact, they perform as good or better than aspirating technologies in high-sensitivity environments. In an aspirating system, the smoke is sensed at one central unit, allowing dilution to negatively affect response time. With Pinnacle, measurement points away from the fire do not degrade response time, regardless of the size of the fire.</p>
<p><strong>Flexibility and Cost Savings</strong></p>
<p>In general, systems that incorporate Pinnacle can be extremely flexible and cost effective. For instance, one fire alarm control panel loop can have a variety of smoke detectors installed on one pair of wires. Only critical areas with high-tech electronic equipment that require ultra-high sensitive smoke detection need to use Pinnacle.</p>
<p>Non-critical areas can simply use standard photoelectric or ionization smoke detectors. Regardless of type, all of the detectors install in the same mounting bases, so system designers can seamlessly mix Pinnacle with other standard detection technologies, thereby reducing overall cost.</p>
<p><a class="a2a_dd a2a_target addtoany_share_save" href="http://www.addtoany.com/share_save#url=http%3A%2F%2Fwww.systemsensor.com%2Flifesafety%2F2009%2F11%2Fproduct-intelligent-smoke-detectors-for-critical-applications%2F&amp;title=Product%3A%20Intelligent%20Smoke%20Detectors%20for%20Critical%20Applications" id="wpa2a_12"><img src="http://www.systemsensor.com/lifesafety/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="Share"/></a></p>]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/lifesafety/2009/11/product-intelligent-smoke-detectors-for-critical-applications/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Industry Update: UL Revises 1971, Signaling Devices for the Hearing Impaired</title>
		<link>http://www.systemsensor.com/lifesafety/2009/11/industry-update-ul-revises-1971-signaling-devices-for-the-hearing-impaired/</link>
		<comments>http://www.systemsensor.com/lifesafety/2009/11/industry-update-ul-revises-1971-signaling-devices-for-the-hearing-impaired/#comments</comments>
		<pubDate>Thu, 12 Nov 2009 18:31:13 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Design and Installation]]></category>
		<category><![CDATA[UL]]></category>
		<category><![CDATA[Winter 2005]]></category>
		<category><![CDATA[A/V Notification]]></category>
		<category><![CDATA[Smoke detection]]></category>
		<category><![CDATA[Speakers and Strobes]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1551</guid>
		<description><![CDATA[New standards cut back system failure risks. In May 2004, Underwriters Laboratories (UL) revised UL 1971, regulating how operating currents are to be measured and how voltage ranges are to be listed and published. Historically, fire-alarm system designers used 24-volt current draw for computing voltage drops on audible and visible (AV) circuits. However, voltage drops [...]]]></description>
			<content:encoded><![CDATA[<p><em>New standards cut back system failure risks.</em></p>
<p>In May 2004, Underwriters Laboratories (UL) revised UL 1971, regulating how operating currents are to be measured and how voltage ranges are to be listed and published.</p>
<p>Historically, fire-alarm system designers used 24-volt current draw for computing voltage drops on audible and visible (AV) circuits. However, voltage drops based on 24-volt current draw only provide an illusion of lower current draw, placing the reliability of the circuit in question.</p>
<p>UL recognized confusion within the industry because AV appliance circuit calculations were being performed with the wrong current draw. They saw the potential for circuit failures.</p>
<p><strong>UL Max to Denote Current Ratings</strong></p>
<p>Seldom is the voltage at AV devices exactly 24 volts. This is due to the natural voltage drop in the circuit. Depending where the device is located on the circuit, the voltage could drop to its lowest operating voltage.</p>
<p>This means that because device currents vary with applied voltage, the only way to assure the power supply will provide enough current to the entire circuit is to measure current for each device at its highest value.</p>
<p>Based on this logic, UL now requires that current-rating published in installation manuals are to symbolize the maximum current draw (UL Max) over the listed voltage range. These true current ratings will:</p>
<p>1. Reflect device power usage more accurately.<br />
2. Ensure compatibility between devices and outputs on the control panel, regardless of manufacturer.<br />
3. Present comparable current-draw data amongst manufacturers.</p>
<p><strong>Incorrect Data is Still Printed Today</strong></p>
<p>Despite UL’s efforts, some manufacturers are still printing 24-volt current draws on their data sheets. Current draws based on 24 volts can confuse industry professionals who don’t realize that these specifications shouldn’t be used for circuit calculations.</p>
<p>To eliminate confusion throughout the industry, System Sensor is advertising a white paper that gives details and examples of the UL 1971 revision.</p>
<p>You can download a free copy of the white paper, and you can sign up for one of System Sensor’s Fire Protection seminars to learn about the latest fire-detection technologies and UL requirements, by visiting System Sensor’s website atwww.systemsensor.com.</p>
<p><a class="a2a_dd a2a_target addtoany_share_save" href="http://www.addtoany.com/share_save#url=http%3A%2F%2Fwww.systemsensor.com%2Flifesafety%2F2009%2F11%2Findustry-update-ul-revises-1971-signaling-devices-for-the-hearing-impaired%2F&amp;title=Industry%20Update%3A%20UL%20Revises%201971%2C%20Signaling%20Devices%20for%20the%20Hearing%20Impaired" id="wpa2a_14"><img src="http://www.systemsensor.com/lifesafety/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="Share"/></a></p>]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/lifesafety/2009/11/industry-update-ul-revises-1971-signaling-devices-for-the-hearing-impaired/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>