<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Life Safety Magazine &#187; Carbon monoxide</title>
	<atom:link href="http://www.systemsensor.com/ls/tag/carbon-monoxide/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.systemsensor.com/ls</link>
	<description>Just another WordPress weblog</description>
	<lastBuildDate>Tue, 31 Aug 2010 14:28:52 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
		<item>
		<title>Easily Upgrade CO Detectors</title>
		<link>http://www.systemsensor.com/ls/2010/08/easily-upgrade-co-detectors/</link>
		<comments>http://www.systemsensor.com/ls/2010/08/easily-upgrade-co-detectors/#comments</comments>
		<pubDate>Wed, 11 Aug 2010 19:01:03 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Carbon Monoxide Detection]]></category>
		<category><![CDATA[Fall 2010]]></category>
		<category><![CDATA[Carbon monoxide]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=2176</guid>
		<description><![CDATA[With the first system-connected carbon monoxide (CO) detectors now reaching their end-of-life, it’s a perfect time for security dealers and installers to upgrade their subscribers to the latest CO detection technology, such as the award-winning CO1224T CO Detector with RealTest™.]]></description>
			<content:encoded><![CDATA[<p>With the first system-connected carbon monoxide (CO) detectors now reaching their end-of-life, it’s a perfect time for security dealers and installers to upgrade their subscribers to the latest CO detection technology, such as the award-winning CO1224T CO Detector with RealTest™.</p>
<p>However, because the footprint of the initial system-connected devices are much larger than the current crop of detectors, new detectors will not completely cover holes or wall outlines left by the old detectors. As a result, CO detector replacement may not be as simple as pulling out the old detector and wiring up a new one, especially in commercial or residential applications where the space’s aesthetic appeal is important.</p>
<p>To address this issue, System Sensor introduces the CO-PLATE detector replacement plate for use with the CO1224T. This new plate mounts in seconds to perfectly cover previously installed CO detector footprints for a clean, low-profile finish ideal for commercial and residential applications.</p>
<p>Most importantly, this new plate makes it easy for installers and customers to benefit from the CO1224T’s unique RealTest technology, which makes the CO1224T the only detector fully compliant with NFPA 720: 2009 CO testing requirements. RealTest enables installers to functionally test the CO sensing cell with a short spray of canned CO. In minutes, the installer can verify that detector is doing its job, protecting customers from deadly CO.</p>
<p><img src="http://www.systemsensor.com/ls/wp-content/uploads/2010/08/product-co1224t.jpg" alt="" title="CO1224T Carbon Monoxide Detector with RealTest™ Technology" width="700" height="257" class="alignnone size-full wp-image-2205" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/ls/2010/08/easily-upgrade-co-detectors/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Carbon Monoxide Training Online</title>
		<link>http://www.systemsensor.com/ls/2010/08/carbon-monoxide-training-online/</link>
		<comments>http://www.systemsensor.com/ls/2010/08/carbon-monoxide-training-online/#comments</comments>
		<pubDate>Wed, 11 Aug 2010 19:00:59 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Carbon Monoxide Detection]]></category>
		<category><![CDATA[Fall 2010]]></category>
		<category><![CDATA[Carbon monoxide]]></category>
		<category><![CDATA[Training]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=2178</guid>
		<description><![CDATA[The System Sensor Carbon Monoxide Online Training course provides a self-training option that can enhance your knowledge of CO detector technology, legislation and applications for use in the field. Take the course whenever and wherever it is most convenient for you. Once you’ve completed the course, you can take an online quiz and print a certificate to verify course completion.]]></description>
			<content:encoded><![CDATA[<p><a href="http://www.systemsensor.com/training/"><img src="http://www.systemsensor.com/ls/wp-content/uploads/2010/08/training.jpg" alt="" title="Carbon Monoxide Training Online" width="340" height="228" class="alignright size-full wp-image-2201" /></a>The System Sensor Carbon Monoxide Online Training course provides a self-training option that can enhance your knowledge of CO detector technology, legislation and applications for use in the field. Take the course whenever and wherever it is most convenient for you. Once you’ve completed the course, you can take an online quiz and print a certificate to verify course completion.</p>
<p>System Sensor also has CO learning options in its webinar archives. “Selling CO Protection” shows you the benefits of offering system-connected CO detection as part of your service and why your customers will want to buy CO detection from you. “Carbon Monoxide Detection: Code and Legislation Updates” provides the latest updates on CO detection state legislation and regulatory mandates. It also recaps many of the key changes to the 2009 edition of NFPA 720.</p>
<p>Online training and webinars can be accessed at <a href="http://www.systemsensor.com/training/">systemsensor.com/training</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/ls/2010/08/carbon-monoxide-training-online/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Selling CO Protection</title>
		<link>http://www.systemsensor.com/ls/2009/11/guidelines-selling-co-protection/</link>
		<comments>http://www.systemsensor.com/ls/2009/11/guidelines-selling-co-protection/#comments</comments>
		<pubDate>Sun, 15 Nov 2009 14:30:55 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Carbon Monoxide Detection]]></category>
		<category><![CDATA[Guidelines]]></category>
		<category><![CDATA[Winter 2009]]></category>
		<category><![CDATA[Carbon monoxide]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1667</guid>
		<description><![CDATA[With all the stories of carbon monoxide (CO) tragedies, your customers are likely becoming more aware of the dangers of CO. Likewise, the numerous stories of tragedies averted by CO detection have proven that CO detectors save lives. As a result, many of your customers are probably already interested in obtaining CO detection.]]></description>
			<content:encoded><![CDATA[<p><img src="http://www.systemsensor.com/ls/wp-content/uploads/2009/11/selling-co-protection.jpg" alt="Selling CO Protection" title="Selling CO Protection" width="454" height="341" class="alignright size-full wp-image-1729" /><em>With all the stories of carbon monoxide (CO) tragedies, your customers are likely becoming more aware of the dangers of CO. Likewise, the numerous stories of tragedies averted by CO detection have proven that CO detectors save lives. As a result, many of your customers are probably already interested in obtaining CO detection.</em></p>
<p><em>Here are five reasons why you should be their provider and three reasons why your customers will want to buy CO detection from you.</em></p>
<h3>Why You Should Provide CO Detection</h3>
<p><strong>1) Capitalize on an expanding market.</strong></p>
<p>As public awareness grows, new local, state and national legislation for CO detection is being adopted. For example, recent CO poisoning tragedies in Colorado were the impetus for passing CO legislation in that state. More than half of the U.S. states already have CO legislation. Several more have legislation pending. (System Sensor keeps an ongoing legislation tally at <a href="http://www.systemsensor.com/co/">www.systemsensor.com/co</a>.)</p>
<p>One thing all this new legislation means for you is that CO detection is a growing market with a built-in customer base. Many of your customers are required now or will likely soon be required to have CO protection. Why shouldn’t you be their provider? With a CO offering, you can differentiate yourself from your competition with an additional service offering while increasing your commission and providing needed life safety protection for your customers.</p>
<p><strong>2) Build longer-term relationships and extend your revenue stream.</strong></p>
<p>Another big reason to offer CO detection is that customers who subscribe to fire protection monitoring are less likely to cancel their security monitoring service. The same is likely to be true for CO detection services. So if you sell CO detection as part of your overall security offering, this can result in less customer attrition and longer-term recurring monthly revenue for you.</p>
<p><strong>3) Gain referrals as a life safety expert and grow your income stream.</strong></p>
<p>While your customers are becoming more educated about the dangers of CO in their homes, they may not be aware that monitoring options are available. In fact, it’s likely that they believe retail detectors are their only option. By providing expertise around life safety solutions and legislation that your competition can’t and offering a CO detection solution, you can gain customer trust and build your business through recommendations to their friends and family.</p>
<p><strong>4) Win jobs over your competition.</strong></p>
<p>With a CO detection option, you can differentiate yourself from your competition with a solid product and service offering while increasing your commission.</p>
<p><strong>5) CO detector guidelines are more clearly defined than ever.</strong><br />
<img src="http://www.systemsensor.com/ls/wp-content/uploads/2009/11/selling-co-protection-tall.jpg" alt="Why Your Customers Will Buy CO Detection from You" title="Why Your Customers Will Buy CO Detection from You" width="227" height="557" class="alignright size-full wp-image-1843" /><br />
The revised 2009 edition of NFPA 720 is a complete rewrite of the CO detection standard. It provides you with information on detector installation, placement, testing and maintenance, and off-premise signal transmission for both commercial and residential occupancies. So you now have the guidance you need to enter confidently into this growing market and provide your customers with the highest level of CO protection available. (System Sensor also offers a free Applications Guide for system-connected CO detectors that you can access at <a href="http://www.systemsensor.com/co">www.systemsensor.com/co</a>.)</p>
<h3>Why Your Customers Will Buy CO Detection from You</h3>
<p><strong>1) CO protection saves lives!</strong></p>
<p>This is the obvious selling point for CO detection. Your customers may have heard about some of the recent CO tragedies, but what they may not have heard is how CO detectors are already saving lives. The most common factor with CO tragedies is there are no operational CO detection devices installed in the occupancy. But all across America, CO detectors are averting tragedies in schools, office buildings and homes.</p>
<p>For your customers, CO detection can provide peace of mind against the “silent killer” of carbon monoxide. There is no other way to protect against it.</p>
<p><strong>2) System-connected detectors provide more protection.</strong></p>
<p>One of the biggest reasons that your customers should be getting their CO protection from you is that monitored detection connected to the security or fire system provides a much higher level of protection than stand-alone retail detectors. Specifically, you can offer 24/7 central station monitoring capabilities that protect your customers when they cannot respond to a local alarm for any reason (i.e., they are not home, they are sleeping or they are already suffering from the effects of CO poisoning). Also, system-connected devices can be monitored to provide proactive maintenance to ensure that CO detectors are providing constant protection with no system downtime due to damage, the end-of-life of the CO cell, or technical and mechanical problems.</p>
<p><strong>3) Many of your customers are already required to have CO protection.</strong></p>
<p>More and more states are requiring CO detection. To meet these requirements, many of your customers are going to get CO protection from somewhere. Service providers who already offer fire and/or security monitoring capabilities are uniquely positioned to provide customers with comprehensive, monitored CO protection services, while ensuring that CO detection is properly installed and maintained.</p>
<p>In addition, if the CO legislation is new in your area, many of your customers may be unaware that they must have CO detection. You can educate them on the laws for your area, while offering them an excellent solution for meeting their CO requirements.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/ls/2009/11/guidelines-selling-co-protection/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Fire Protection Specialists Lend Consulting, Inspection Expertise</title>
		<link>http://www.systemsensor.com/ls/2009/11/qa-fire-protection-specialists-lend-consulting-inspection-expertise/</link>
		<comments>http://www.systemsensor.com/ls/2009/11/qa-fire-protection-specialists-lend-consulting-inspection-expertise/#comments</comments>
		<pubDate>Sun, 15 Nov 2009 14:00:34 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Q & A : Ask the Expert]]></category>
		<category><![CDATA[Winter 2009]]></category>
		<category><![CDATA[A/V Notification]]></category>
		<category><![CDATA[Carbon monoxide]]></category>
		<category><![CDATA[Fire sprinklers]]></category>
		<category><![CDATA[Q&A]]></category>
		<category><![CDATA[Smoke detection]]></category>
		<category><![CDATA[Speakers and Strobes]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1669</guid>
		<description><![CDATA[Keith S. Frangiamore is vice president of operations at Fire Safety Consultants, Inc. (FSCI), Elgin, Ill., and a certified fire protection specialist. FSCI, one of the largest private fire protection plan review service companies in the United States, provides review services for many U.S. municipalities and fire departments, as well as for private companies throughout the world. FSCI’s project list includes soccer stadiums, hospitals, casinos and data storage warehouses.]]></description>
			<content:encoded><![CDATA[<p><img src="http://www.systemsensor.com/ls/wp-content/uploads/2009/11/keith-s-frangiamore.jpg" alt="Keith S. Frangiamore, vice president of operations at Fire Safety Consultants, Inc. (FSCI)" title="Keith S. Frangiamore, vice president of operations at Fire Safety Consultants, Inc. (FSCI)" width="227" height="269" class="alignright size-full wp-image-1741" /><em>Keith S. Frangiamore is vice president of operations at Fire Safety Consultants, Inc. (FSCI), Elgin, Ill., and a certified fire protection specialist. FSCI, one of the largest private fire protection plan review service companies in the United States, provides review services for many U.S. municipalities and fire departments, as well as for private companies throughout the world. FSCI’s project list includes soccer stadiums, hospitals, casinos and data storage warehouses.</em></p>
<p><strong>Q. What does a fire safety consultant do?</strong></p>
<p>A. We provide plan review services for municipalities, building owners, architects and engineers. We review the building and/or the fire protection plans, specifications and hydraulic calculations for strict compliance with state and local codes. Additionally, we provide complete building code consulting, site review and inspection services, seminars, fire service planning and management, and fire investigations.</p>
<p>Fire consultants inspect and witness both new and existing fire protection/building code system testing. We will typically perform a cursory site visit, prepare a proposal for the work to be performed and contact the local code official for more information. For municipalities, for example, we inspect the systems for compliance with required codes and approved plans. Then we provide the municipality with a report on the inspections, tests performed and recommendations.</p>
<p><strong>Q. What does a report usually contain?</strong></p>
<p>A. A report outlines actions needed to meet requirements about any code issues related to fire protection or fire protection systems and good fire protection practices. Fire consultants’ reports normally will outline options available and explain each of them fully, including their financial impact.</p>
<p><strong>Q. What types of inspections and tests are required in fire inspections?</strong></p>
<p>A. The required tests and inspections depend on the type of system(s) that are present in the project or occupancy. The plan review letter details the required tests that must be scheduled for each type of system that has been submitted for approval.</p>
<p><strong>Q. What is the sequence for the required tests and inspections in buildings with multiple systems?</strong></p>
<p>A. During site work, the underground fire service water main is completed and tested first. Once the underground has been flushed for both the clean water sample and the required NFPA 24 flush test, the sprinkler system can be connected to the lateral feed main. Then the fire sprinkler system hydrostatic test and rough inspection takes place. The fire alarm system acceptance test is performed when the system is installed and connected to the monitoring agency. Commercial kitchen wet chemical systems, FM200 systems and dry chemical systems can be inspected and tested whenever they are completed. Final inspections on all systems then verify full operation at the time of occupancy.</p>
<p><strong>Q. What suggestions do you have for contractors and installers to make the process go more smoothly?</strong></p>
<p>A. First, get a copy of the latest NFPA 72. There are useful, reproducible forms in the annex, such as submittals, testing forms and the latest information on the decibel requirements. In many renovations or additions, voltage calculations should be addressed. Make sure the voltage to the new area meets requirements. Caution should be used not to overload the system. The audibility at the end of the line could vary as much as 20 dB or more.</p>
<p>Recently, we determined that the smoke/fire detection system for a five-story high-rise with multiple wings and hundreds of units did not meet audibility requirements. Almost the entire building had to be rewired.</p>
<p><strong>Q. How do you prevent such a problem from happening?</strong></p>
<p>Companies such as ours can provide the up-front review of drawings before the actual work begins. We strongly suggest this before submitting to the Authority Having Jurisdiction. Also, allow for new technologies in your plans, and submit complete and accurate plans with as much information as possible. Check for obsolescence of upgrades of existing detectors or alarms. Rapid changes occur regularly in the industry.</p>
<p><strong>Q. How much do inspections typically cost? Who is responsible to pay inspection costs?</strong></p>
<p>Costs depend on the jurisdiction and the fees paid for the plan review. In some cases, the plan review fee includes one or two site inspections. If more than two site visits are required for system(s) approval, additional fees may be required based on an hourly rate.</p>
<p>Typically, the contractor is responsible for all costs associated with site work. If additional fees are required for field work, the responsible party must pay those fees in advance unless other arrangements are made.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/ls/2009/11/qa-fire-protection-specialists-lend-consulting-inspection-expertise/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Providing Solutions vs. Meeting Code</title>
		<link>http://www.systemsensor.com/ls/2009/11/providing-solutions-vs-meeting-code/</link>
		<comments>http://www.systemsensor.com/ls/2009/11/providing-solutions-vs-meeting-code/#comments</comments>
		<pubDate>Sun, 15 Nov 2009 13:30:02 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Carbon Monoxide Detection]]></category>
		<category><![CDATA[Editorial]]></category>
		<category><![CDATA[Intelligent Detection]]></category>
		<category><![CDATA[Winter 2009]]></category>
		<category><![CDATA[Carbon monoxide]]></category>
		<category><![CDATA[Multi-criteria Detection]]></category>
		<category><![CDATA[Smoke detection]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1659</guid>
		<description><![CDATA[Often people say they want the best, but their spending demonstrates that “adequate” is good enough. We talk to system designers who recommend solutions for their customers that would provide better fire and life safety protection than what code requires. But they ultimately end up providing the bare minimum protection required at the customer’s request. [...]]]></description>
			<content:encoded><![CDATA[<p><img src="http://www.systemsensor.com/ls/wp-content/uploads/2009/11/editorial-2009-winter.jpg" alt="Providing Solutions vs. Meeting Code" title="Providing Solutions vs. Meeting Code" width="710" height="385" class="alignnone size-full wp-image-1696" />Often people say they want the best, but their spending demonstrates that “adequate” is good enough. We talk to system designers who recommend solutions for their customers that would provide better fire and life safety protection than what code requires. But they ultimately end up providing the bare minimum protection required at the customer’s request.</p>
<p>The reality is, the customer’s decision usually comes down to money, and it’s difficult to justify extra expenditures in this economy. Yet some dealers are reporting an uptick in system sales. How? By solving their customers’ problems and providing systems that may carry a higher up-front cost but will save their customers money in the long run.</p>
<p>It just goes to show that people are willing to pay for what clearly provides value to them. Those of us in the industry know it’s important not to skimp on critical fire and life safety systems, but do our customers always know when more advanced technology can provide higher returns on their investment and increased performance?</p>
<p>The Rumba Room, a Hollywood nightclub, is a prime example of how site problems revealed the inadequacies of a basic system (<a href="http://www.systemsensor.com/ls/2009/11/meeting-the-nuisance-alarm-challenge/">see cover story</a>). The club, which previously experienced frequent, costly and disruptive nuisance alarms, has now installed the System Sensor Advanced Multi-Criteria Fire Detector. This technology exceeds what the nightclub was required to install, but the payback has been enormous in both life safety protection and cost savings.</p>
<p>This issue also offers tips for enhancing business by expanding service options with carbon monoxide (CO) detection. “CO Detector Saves the Day” is not the type of headline you’ll typically read in a newspaper; a story about a CO incident with tragic results is more common. But if the industry does a better job of promoting system-connected CO detection, people will eventually come to understand the benefits of CO monitoring, and we’ll read fewer stories about preventable CO-related deaths.</p>
<p>Together, let’s educate the market about why better protection systems and services are worthwhile for personal, as well as financial, reasons. Go to <a href="http://www.systemsensor.com/ls/2009/11/system-sensor-online-system-sensor-expands-training-opportunities/">System Sensor Expands Training Opportunities</a> to read how System Sensor is adding training options for professionals. When each of us has more knowledge about fire and life safety systems, we can then share that information with customers and improve service and protection. It’s a win-win for all of us.</p>
<p> <br />
<img src="http://www.systemsensor.com/ls/wp-content/uploads/2009/11/todd-alford.jpg" alt="Todd Alford - Marketing Manager" title="Todd Alford - Marketing Manager" width="227" height="54" class="alignnone size-full wp-image-1695" /><br />
Todd Alford</p>
<p>Marketing Manager — Commercial Business Unit</p>
<p><a class="a2a_dd addtoany_share_save" href="http://www.addtoany.com/share_save"><img src="http://www.systemsensor.com/ls/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="Share/Bookmark"/></a> </p>]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/ls/2009/11/providing-solutions-vs-meeting-code/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>System Sensor Expands Training Opportunities</title>
		<link>http://www.systemsensor.com/ls/2009/11/system-sensor-online-system-sensor-expands-training-opportunities/</link>
		<comments>http://www.systemsensor.com/ls/2009/11/system-sensor-online-system-sensor-expands-training-opportunities/#comments</comments>
		<pubDate>Sun, 15 Nov 2009 13:00:15 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Carbon Monoxide Detection]]></category>
		<category><![CDATA[Intelligent Detection]]></category>
		<category><![CDATA[Seminars]]></category>
		<category><![CDATA[Winter 2009]]></category>
		<category><![CDATA[Carbon monoxide]]></category>
		<category><![CDATA[Multi-criteria Detection]]></category>
		<category><![CDATA[online]]></category>
		<category><![CDATA[Training]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1671</guid>
		<description><![CDATA[As 2009 closes out and we enter 2010, System Sensor is ramping up its training options through multiple channels to meet the growing demand for useful and easily accessible fire and life safety training. Specifically, System Sensor is focused on expanding and improving training options through three key access points: Webinars, Online Training and Seminars.]]></description>
			<content:encoded><![CDATA[<p>As 2009 closes out and we enter 2010, System Sensor is ramping up its training options through multiple channels to meet the growing demand for useful and easily accessible fire and life safety training. Specifically, System Sensor is focused on expanding and improving training options through three key access points: Webinars, Online Training and Seminars.</p>
<p><strong>Webinars</strong></p>
<p>This new Webinar series will focus on providing relevant and timely information on products, market trends, and legislation and enable you to have your questions answered from the comfort of your home or office. There will be multiple chances for you to sign up and attend a live version of each Webinar. Just go to <a href="http://www.systemsensor.com/training/">systemsensor.com/training</a> to check the schedule and register. If you can’t attend the live presentation, System Sensor will be archiving each presentation for you to view at your convenience.</p>
<p>Archives will include the October Webinar, <em>Meet the New Problem Solver: Advanced Multi-Criteria Fire Detector</em>, which introduces you to the world’s most accurate fire detector for your most challenging applications. In this 35-minute Webinar, you’ll learn about the advanced technology that enables this detector to provide the highest levels of sensitivity, while maintaining unmatched nuisance immunity. You’ll see a case study that shows the detector solving highly challenging, real-world problems. And you’ll get an overview of ideal applications for this amazing new technology.</p>
<p>Our November Webinar will be: <em>Selling CO Protection: Don’t Leave Money on the Table</em>. With increased legislation and higher public awareness, carbon monoxide detection is a quickly growing market. See how you can provide your customers with the most comprehensive CO protection available while building your business.</p>
<p><strong>Online Training</strong></p>
<p>System Sensor is updating its Online Training courses with new voiceover options, appealing and informative visuals, and increased interactivity to provide you the information you need at a time and place that is most convenient for you.</p>
<p>These online courses provide a self-training option that can enhance your product and application knowledge for use in the field. Courses cover a wide range of subjects, including product overviews, installation and maintenance, and legislation. Once you have completed the course, you have the option to take an online quiz and print a certificate to verify you have completed the course.</p>
<p>The newest addition to the System Sensor Online Training course lineup updates our Carbon Monoxide Detection Online Training Course. Early next year, new courses will focus on the Advanced Multi-Criteria Fire Detector and nuisance alarm reduction, as well as mass notification.</p>
<p>You can access Online Training at <a href="http://www.systemsensor.com/training/">systemsensor.com/training</a>. System Sensor will be adding more training modules all the time, so check back frequently.</p>
<p><strong>Seminars</strong></p>
<p>System Sensor Seminars provide live training on a variety of topics from the industry’s most knowledgeable fire system and life safety experts. Seminars are free to attend, often provide CEU credits and enable you to interact directly with the instructor.</p>
<p>In 2010, System Sensor will launch Fire Protection Technology and Design Seminars in many cities throughout the U.S. Subjects will include:</p>
<p>• Notification appliance applications</p>
<p>• Voice evacuation systems</p>
<p>• Mass notification systems</p>
<p>• Carbon monoxide detection, codes and legislation</p>
<p>• Multi-criteria and specialty detection</p>
<p>• Duct detector applications</p>
<p>• Update on NFPA changes</p>
<p>In January, check to see which Seminars are coming to your area at <a href="http://www.systemsensor.com/training/">systemsensor.com/training</a>. These events fill up quickly, so be sure to sign up early.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/ls/2009/11/system-sensor-online-system-sensor-expands-training-opportunities/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Editorial: An Additional Layer of Protection</title>
		<link>http://www.systemsensor.com/ls/2009/11/editorial-an-additional-layer-of-protection/</link>
		<comments>http://www.systemsensor.com/ls/2009/11/editorial-an-additional-layer-of-protection/#comments</comments>
		<pubDate>Thu, 12 Nov 2009 18:33:49 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Carbon Monoxide Detection]]></category>
		<category><![CDATA[Editorial]]></category>
		<category><![CDATA[Winter 2006]]></category>
		<category><![CDATA[Carbon monoxide]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1299</guid>
		<description><![CDATA[System Sensor realized several years ago a growing need to expand its product portfolio to provide its customers with protection against the dangers of carbon monoxide poisoning, the leading cause of accidental poisoning death in America. Carbon monoxide is a colorless, odorless, deadly gas produced by burning any kind of fossil fuel. System Sensor found [...]]]></description>
			<content:encoded><![CDATA[<p><img src="http://www.systemsensor.com/ls/wp-content/uploads/2009/10/editorial-an-additional-layer-of-protection.jpg" alt="Editorial An additional layer of protection" title="Editorial An additional layer of protection" width="710" height="372" class="alignnone size-full wp-image-1353" />System Sensor realized several years ago a growing need to expand its product portfolio to provide its customers with protection against the dangers of carbon monoxide poisoning, the leading cause of accidental poisoning death in America. Carbon monoxide is a colorless, odorless, deadly gas produced by burning any kind of fossil fuel.</p>
<p>System Sensor found that legislative bodies and major municipalities across the United States were passing laws that required the installation of carbon monoxide detectors in new and retrofitted buildings. In fact, during the past decade, 11 states, mostly clustered in the northern region, and large cities like New York, Chicago, Charlotte and St. Louis, passed resolutions to better protect their constituencies from the danger carbon monoxide poses. Several other states have pending legislation.</p>
<p>Just as regulation played a key role in the growth of system-connected smoke detectors, we believe regulation will be a key factor in the growth of system-connected CO detectors. These ordinances will aid in the adoption of CO detectors in the market.</p>
<p>What System Sensor found, however, was a market void. As a result, the company developed the only UL 2075 compliant system-connected carbon monoxide detector available on the market. The CO1224 carbon monoxide detector meets Underwriter Laboratories’ standard by incorporating a code-required trouble relay into the device. This allows the CO1224 to communicate with the system, for instance, by sending a sensor end-of-life signal to the control panel. No other carbon monoxide detector has this code-required capability. Additionally, the CO1224 incorporates SEMS-type terminal Philips-head screws to provide a quicker and more positive wiring connection while facilitating code-required wiring supervision.</p>
<p>We will continue to look for new products, because providing products that protect the lives of our customers is more than an ideal. It is our way of life.<br />
<img src="http://www.systemsensor.com/ls/wp-content/uploads/2009/10/richard-roberts.gif" alt="Richard Roberts" title="Richard Roberts" width="216" height="131" class="alignnone size-full wp-image-1354" /><br />
Richard Roberts</p>
<p>Product Manager<br />
Security Business Unit</p>
<p><a class="a2a_dd addtoany_share_save" href="http://www.addtoany.com/share_save"><img src="http://www.systemsensor.com/ls/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="Share/Bookmark"/></a> </p>]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/ls/2009/11/editorial-an-additional-layer-of-protection/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Factors to Address in Fire- and Life-Safety Design</title>
		<link>http://www.systemsensor.com/ls/2009/11/factors-to-address-in-fire-and-life-safety-design/</link>
		<comments>http://www.systemsensor.com/ls/2009/11/factors-to-address-in-fire-and-life-safety-design/#comments</comments>
		<pubDate>Thu, 12 Nov 2009 18:33:07 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Audible/Visible Notification]]></category>
		<category><![CDATA[Carbon Monoxide Detection]]></category>
		<category><![CDATA[Commercial]]></category>
		<category><![CDATA[Cover Features]]></category>
		<category><![CDATA[Education]]></category>
		<category><![CDATA[Fall 2007]]></category>
		<category><![CDATA[Hospitality]]></category>
		<category><![CDATA[NFPA]]></category>
		<category><![CDATA[Residential]]></category>
		<category><![CDATA[A/V Notification]]></category>
		<category><![CDATA[Carbon monoxide]]></category>
		<category><![CDATA[Smoke detection]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1280</guid>
		<description><![CDATA[Robert E. Solomon, P.E., National Fire Protection Association, tells how identifying building use, occupancy and other factors impacts planning for an appropriate system. A comprehensive fire- and life-safety design requires a cohesive blend of alarm/detection capabilities, an appropriate suppression system and a number of other building construction features that depend on occupancy, type of facility [...]]]></description>
			<content:encoded><![CDATA[<p><img src="http://www.systemsensor.com/ls/wp-content/uploads/2009/10/cover-factors-to-address.jpg" alt="Factors to Address in Fire- and Life-Safety Design" title="Factors to Address in Fire- and Life-Safety Design" width="227" height="326" class="alignright size-full wp-image-1405" /><em>Robert E. Solomon, P.E., National Fire Protection Association, tells how identifying building use, occupancy and other factors impacts planning for an appropriate system.</em></p>
<p>A comprehensive fire- and life-safety design requires a cohesive blend of alarm/detection capabilities, an appropriate suppression system and a number of other building construction features that depend on occupancy, type of facility and use of space. An often overlooked component — planning — is integral to keeping occupants safe.</p>
<p>In buildings, like an apartment complex, the alarm and detection system is a critical component because occupants may be asleep. Alarm and detection features can provide functions such as early warning for occupants, fire department notification and unlocking of doors. In large public venues, like a shopping mall or arena, the notification system may integrate a voice-communication function to give emergency instruction.</p>
<p>For healthcare occupancies, correctional facilities, high-rise buildings or other places where evacuation would cause considerable disturbance or not be a desired option, suppression becomes the focus of the system.</p>
<p>“An automatic fire sprinkler system has the ability to control the situation, thereby limiting the effects of the fire, the generation of products of combustion, and in general, allowing additional time for occupants to move to a safe area,” said Solomon.“Of course, the presence of a well-thought-out means of egress, with adequate exits, stairs and doors, is also crucially important.”</p>
<p>In general terms, the means of egress should also be thought of as a “system,” as well. The number, type and arrangement of the egress components are important factors to consider.</p>
<p>Some construction options may require the integration of firewalls, fire barrier walls and smoke compartments, as well as protection schemes for vertical openings between floors.</p>
<p>“There are even criteria for interior finish materials such as floor, wall and ceiling coverings,” explained Solomon.“Each of these building construction features can be specified to achieve the desired level of fire resistance, which is usually measured in hours for a firewall based on the building’s structural system, or for flame spread and smoke-developed characteristics for an interior wall finish. The level of fire-safety performance intended for the building is contingent upon the use of the occupancy.”<br />
<img src="http://www.systemsensor.com/ls/wp-content/uploads/2009/10/cover-devices.jpg" alt="Devices" title="Devices" width="710" height="193" class="alignnone size-full wp-image-1406" /></p>
<p><a class="a2a_dd addtoany_share_save" href="http://www.addtoany.com/share_save"><img src="http://www.systemsensor.com/ls/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="Share/Bookmark"/></a> </p>]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/ls/2009/11/factors-to-address-in-fire-and-life-safety-design/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Continuous Product Development</title>
		<link>http://www.systemsensor.com/ls/2009/11/continuous-product-development/</link>
		<comments>http://www.systemsensor.com/ls/2009/11/continuous-product-development/#comments</comments>
		<pubDate>Thu, 12 Nov 2009 18:33:03 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Carbon Monoxide Detection]]></category>
		<category><![CDATA[Editorial]]></category>
		<category><![CDATA[Fall 2007]]></category>
		<category><![CDATA[Intelligent Detection]]></category>
		<category><![CDATA[Carbon monoxide]]></category>
		<category><![CDATA[Smoke detection]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1278</guid>
		<description><![CDATA[Whether you’re installing a fire- and life-safety system to protect occupants of a school or nursing home, or to avoid business interruption, you need the right technology for the job. As you know, the basic smoke detector frequently used in commercial buildings is not always the answer to protect a warehouse or an exposed parking [...]]]></description>
			<content:encoded><![CDATA[<p><img src="http://www.systemsensor.com/ls/wp-content/uploads/2009/10/continuous-product-development.jpg" alt="Continuous Product Development" title="Continuous Product Development" width="710" height="300" class="alignnone size-full wp-image-1412" />Whether you’re installing a fire- and life-safety system to protect occupants of a school or nursing home, or to avoid business interruption, you need the right technology for the job.</p>
<p>As you know, the basic smoke detector frequently used in commercial buildings is not always the answer to protect a warehouse or an exposed parking garage. There are other, more application-specific technologies that have been developed for those different environments.</p>
<p>System Sensor puts a strong emphasis on product development to ensure that we can provide the most appropriate — and most advanced — technologies for our customers and their fire protection needs. Standard fire detection and notification remain an important part of our product line-up. We have also branched into other related fire- and life-safety areas.</p>
<p>Newer technologies include our high-sensitivity smoke detectors, which we developed for highly sensitive environments that require very early warning (see “Bell Canada Relies on System Sensor’s New Laser Duct Smoke Detectors”).</p>
<p>Gas detection for protection against carbon monoxide is another area where System Sensor continues to conduct a great deal of research and product development. Our CO1224 carbon monoxide detector is an industry first — a detector specifically designed for system operation. This detector, along with our monitored smoke alarm detectors, is a logical extension to protecting people from danger. In each of these product areas, System Sensor knows it’s not enough to just meet the letter of the law. System Sensor wants to bring customers the highest level of protection possible from different life- and property-threatening emergencies.</p>
<p>System Sensor will continue to develop other, more diverse technologies that can cover the full gamut of potential fire and smoke scenarios. We’re committed to covering all the bases in detection and notification with the right technology for the job.<br />
<img src="http://www.systemsensor.com/ls/wp-content/uploads/2009/10/jeff-klein.gif" alt="Jeff Klein" title="Jeff Klein" width="227" height="45" class="alignnone size-full wp-image-1411" /><br />
Jeff Klein</p>
<p>Commercial Business Line Leader</p>
<p><a class="a2a_dd addtoany_share_save" href="http://www.addtoany.com/share_save"><img src="http://www.systemsensor.com/ls/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="Share/Bookmark"/></a> </p>]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/ls/2009/11/continuous-product-development/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Innovation: The Mark of a Leader</title>
		<link>http://www.systemsensor.com/ls/2009/11/innovation-the-mark-of-a-leader/</link>
		<comments>http://www.systemsensor.com/ls/2009/11/innovation-the-mark-of-a-leader/#comments</comments>
		<pubDate>Thu, 12 Nov 2009 18:32:58 +0000</pubDate>
		<dc:creator>maria</dc:creator>
				<category><![CDATA[Audible/Visible Notification]]></category>
		<category><![CDATA[Carbon Monoxide Detection]]></category>
		<category><![CDATA[Editorial]]></category>
		<category><![CDATA[Fall 2008]]></category>
		<category><![CDATA[HVAC Monitoring]]></category>
		<category><![CDATA[A/V Notification]]></category>
		<category><![CDATA[Carbon monoxide]]></category>
		<category><![CDATA[HVAC]]></category>

		<guid isPermaLink="false">http://www.systemsensor.com/ls/?p=1266</guid>
		<description><![CDATA[“Necessity [is] the mother of invention,” penned playwright George Farquhar. Many fire and life safety products have come about following tragedy. Cries for change immediately following major fires have led to new laws and building code changes, and oftentimes they have served as the impetus for new technologies that better protect people and property. Then [...]]]></description>
			<content:encoded><![CDATA[<p><img src="http://www.systemsensor.com/ls/wp-content/uploads/2009/10/editorial-innovation.jpg" alt="Innovation: The Mark of a Leader" title="Innovation: The Mark of a Leader" width="710" height="352" class="alignnone size-full wp-image-1415" /><br />
“Necessity [is] the mother of invention,” penned playwright George Farquhar. Many fire and life safety products have come about following tragedy. Cries for change immediately following major fires have led to new laws and building code changes, and oftentimes they have served as the impetus for new technologies that better protect people and property.</p>
<p>Then there are times when there’s nothing wrong with the available technology. It’s just that inventive minds think of ways that the technology can be better utilized to serve our customers’ needs. That’s what happened in the case of several of the new products that System Sensor is announcing in this issue of LifeSafety.</p>
<p>The first is our new Advanced Multi-Criteria Fire Detector, which acts as four sensors in one. System Sensor has manufactured products that provide smoke, heat, carbon monoxide and flame detection, predominantly utilizing singular sensors. In the interest of offering the ultimate in fire detection while addressing the longstanding problem of nuisance alarms, we have brought these four detection elements together with advanced, logical algorithms that work collectively to analyze and determine whether there truly is a fire.</p>
<p>The second innovation is the new CO1224T carbon monoxide detector, which provides a simple, inexpensive test to confirm the CO cell’s functionality using canned CO. A one-second test spray lets you rest assured that the CO sensor is functioning properly — a feature that puts System Sensor well ahead of the upcoming NFPA 720-2009 standard for CO devices.</p>
<p>Our third solution, which reflects your feedback on our Innovair™ line of duct smoke detectors, is the new InnovairFlex™ series duct detectors. InnovairFlex detectors offer the ultimate in flexibility and functionality, whether it’s broader environmental specifications, greater wiring capabilities, enhanced sensor status indication or even the detector’s physical footprint.</p>
<p>System Sensor engineering and product development teams continuously strive to not only improve existing detection and notification products, but to define the future standard for the industry. Interestingly enough, our methodology is fairly commonsensical — seek to identify and understand customers’ unmet needs. However, it’s the combination of our customer focus and the application of our leading technology that allows us to continually deliver innovative solutions such as these.</p>
<p>Thank you for the continued opportunity to serve your fire and life safety needs.<br />
<img src="http://www.systemsensor.com/ls/wp-content/uploads/2009/10/tom-potosnak.gif" alt="Tom Potosnak" title="Tom Potosnak" width="227" height="52" class="alignnone size-full wp-image-1414" /><br />
Tom Potosnak</p>
<p>General Manager<br />
System Sensor U.S.</p>
<p><a class="a2a_dd addtoany_share_save" href="http://www.addtoany.com/share_save"><img src="http://www.systemsensor.com/ls/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="Share/Bookmark"/></a> </p>]]></content:encoded>
			<wfw:commentRss>http://www.systemsensor.com/ls/2009/11/innovation-the-mark-of-a-leader/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
