System Sensor News Release

FOR IMMEDIATE RELEASE

For more information contact:
David George (630) 377-6674 x1385
Jim Nowakowski (847) 358-4848

SUMMARY: NEW BEAM200 SINGLE-ENDED, INTELLIGENT BEAM SMOKE DETECTORS FROM SYSTEM SENSOR FOR DIFFICULT OPEN-SPACE AND HIGH-CEILING INSTALLATIONS

St. Charles, IL –System Sensor’s intelligent, single-ended, reflected-type BEAM200 Smoke Detectors are perfect for protecting open areas with high ceilings where other methods of smoke detection are difficult to install and maintain.

Alignment via an optical sight and a 2-digit signal strength meter makes installation of the System Sensor BEAM200 much easier than dual-ended projected beam detectors. Listed for operation from –22°F to 131°F, the BEAM200 is designed for open-area applications to provide early warning in environments where temperature extremes exceed the capability of other types of smoke detection. BEAM200 provides 16 to 328-foot protection coverage.

The BEAM200 consists of a transmitter/receiver unit and a reflector. When smoke enters the area between the unit and the reflector it causes a reduction in the signal and, when the smoke level reaches the predetermined threshold, an alarm is activated.

System Sensor’s BEAM200 has four standard sensitivity selections in addition to two Acclimate™ settings. When either Acclimate setting is selected, the detector automatically adjusts its sensitivity using advanced software algorithms to determine the optimum sensitivity for the environment. The BEAM200S is equipped with an integral sensitivity test feature that consists of a test filter attached to a servo motor inside the detector optics. Using the remote test station RTS451, the motor is activated and moves the filter in the pathway of the light beam, thereby testing detector sensitivity. The test feature can also be activated by an on-board test button. This integral sensitivity test feature allows the user to quickly and easily meet the annual maintenance and test requirements of NFPA 72.

System Sensor is a global manufacturer of fire detection and notification devices, specializing in smoke detection and notification technology. System Sensor places a premium on research and development, resulting in products that are reliable, sophisticated and designed for real-world applications. With sales, service and manufacturing facilities throughout the Americas, Europe and Asia, System Sensor’s high quality, innovative products are the most comprehensive in the industry.

For more information on the company’s Beam Smoke Detector, contact System Sensor – 3825 Ohio Avenue, St. Charles , IL 60174. Telephone (800) 736-7672 or visit our website at www.systemsensor.com.

# # #

SYS3106

Image: System Sensor’s BEAM200: Intelligent, Single-Ended, Reflected-Type Beam Smoke Detector

NOTE: Please forward leads to System Sensor, 553 N. North Court, Ste. 110, Palatine IL 60067 or email leads@interlinegroup.com.

Honeywell International is a $34 billion diversified technology and manufacturing leader, serving customers worldwide with aerospace products and services; control technologies for buildings, homes and industry; automotive products; turbochargers; and specialty materials. Based in Morris Township, N.J., Honeywell's shares are traded on the New York, London and Chicago Stock Exchanges. It is one of the 30 stocks that make up the Dow Jones Industrial Average and is also a component of the Standard & Poor's 500 Index. For additional information, please visit www.honeywell.com .

This release contains forward-looking statements as defined in Section 21E of the Securities Exchange Act of 1934, including statements about future business operations, financial performance and market conditions. Such forward-looking statements involve risks and uncertainties inherent in business forecasts as further described in our filings under the Securities Exchange Act.