Audible Visible Notification
| Search for: av-horn-strobes | SpectrAlert Advance |
|
P2WK
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P2WK is a white, two-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.
|
|
|
P2WHK
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P2WHK is a white, two-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.
|
|
|
P4WK
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P4WK is a white, four-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.
|
|
|
PC2WK
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance PC2WK is a white, two-wire, ceiling-mount outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.
|
|
|
PC2WHK
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance PC2WHK is a white, two-wire, outdoor, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.
|
|
|
PC4WK
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance PC4WK is a white, four-wire, outdoor, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.
|
|
|
PC4WHK
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance PC4WHK is a white, four-wire, outdoor, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.
|
|
|
P2R
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P2R is a red, two-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
P2R-P
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance P2R-P is an unmarked, red, two-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
P2R-SP
Data Sheet (pdf)
Installation Instructions (pdf)
Marked with "FUEGO," the SpectrAlert Advance P2R-SP is a red, two-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
P2RH
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P2RH is a red, two-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
|
|
P2RK
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P2RK is a red, two-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.
|
|
|
P2RK-P
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance P2RK-P is an unmarked, red, two-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.
|
|
|
P2RK-R
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance P2RK-R (replacement model) is a red, two-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Offers mounting plate only - no back box included.
|
|
|
P2RHK
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P2RHK is a red, two-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.
|
|
|
P2RHK-P
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance P2RHK-P is an unmarked red, two-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.
|
|
|
P2RHK-R
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance P2RHK-R (replacement model) is a red, two-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Offers mounting plate only - no back box included.
|
|
|
P2W
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P2W is a white, two-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
P2W-P
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance P2W-P is an unmarked, white, two-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
P2WH
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P2WH is a white, two-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
|
|
P2WH-P
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance P2WH-P is an unmarked, white, two-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
|
|
P2WK-P
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance P2WK-P is an unmarked, white, two-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.
|
|
|
P2WHK-P
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance P2WHK-P is an unmarked, white, two-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.
|
|
|
P4R
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P4R is a red, four-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
P4RH
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P4RH is a red, four-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
|
|
P4RK
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P4RK is a red, four-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
P4RK-R
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance P4RK-R (replacement model) is a red, four-wire, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Offers mounting plate only - no back box included.
|
|
|
P4W
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P4W is a white, four-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
P4W-P
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance P4W-P is an unmarked, white, four-wire horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
PC2R
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance PC2R is a red, two-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
PC2R-P
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance PC2R-P is an unmarked, red, two-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
PC2RH
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance PC2RH is a red, two-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
|
|
PC2RK
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance PC2RK is a red, two-wire, ceiling-mount, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Outdoor back box included.
|
|
|
PC2RHK
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance PC2RHK is a red, two-wire, ceiling-mount, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.
|
|
|
PC2W
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance PC2W is a white, two-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
PC2W-P
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance PC2W-P is an unmarked, white, two-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
PC2W-SP
Data Sheet (pdf)
Installation Instructions (pdf)
Marked with "FUEGO," the SpectrAlert Advance PC2W-SP is a white, two-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
P4R-P
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance P4R-P is an unmarked, red, four-wire horn strobe with selectable
strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
PC2WH
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance PC2WH is a white, two-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
|
|
PC2WH-P
Data Sheet (pdf)
Installation Instructions (pdf)
The SpectrAlert Advance PC2WH-P is an unmarked, white, two-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
|
|
PC4R
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance PC4R is a red, four-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
|
PC4RH
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance PC4RH is a red, four-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
|
|
P2RHK-120
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance P2RHK-120 is a red, 120 V, selectable-output, outdoor horn strobe.
|
|
|
PC4W
Data Sheet (pdf)
Installation Instructions (pdf)
Engineering Specs
The SpectrAlert Advance PC4W is a white, four-wire, ceiling-mount horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
|
Discontinued Products
| Discontinued Model |
Installation Instructions |
Data Sheet |
Replacement Model |
| P12015K |
 |
 |
P2RHK-120 |
The SpectrAlert P12015K is a red, 120 VAC horn with a built-in 15-candela strobe intended for outdoor use.
|
| P121575 |
 |
 |
P2R, P4R |
The SpectrAlert P121575 is a red, 12-volt horn with a built-in 15/75-candela strobe.
|
| P121575K |
 |
 |
P2RK, P4RK |
The SpectrAlert P121575K is a weatherproof, red, 12-volt horn with a built-in 15/75-candela strobe.
|
| P121575W |
 |
 |
P2W, P4W |
The SpectrAlert P121575W is a white, 12-volt horn with a built-in 15/75-candela strobe.
|
| P1215W |
 |
 |
P2W, P4W |
The SpectrAlert P1215W is a white, 12-volt horn with a built-in 15-candela strobe.
|
| P1224MC |
 |
 |
P2R, P4R |
The SpectrAlert P1224MC is a red, selectable-output horn strobe that self-adjusts for either 12- or 24-volt operation.
|
| P1224MCK |
 |
 |
P2RK, P4RK |
The SpectrAlert P1224MCK is an outdoor, red, selectable-output horn strobe that self-adjusts for either 12- or 24-volt operation.
|
| P1224MCP |
 |
 |
P2R-P, P4R-P |
The SpectrAlert P1224MCP is a red, selectable-output horn strobe (unmarked housing) that self-adjusts for either 12- or 24-volt operation.
|
| P1224MCPW |
 |
 |
P2W-P, P4W-P |
The SpectrAlert P1224MCPW is a white, selectable-output horn strobe (unmarked housing) that self-adjusts for either 12- or 24-volt operation.
|
| P1224MCSP |
 |
 |
P2R-SP, P4R-SP |
The SpectrAlert P1224MCSP is a red, selectable-output horn strobe ("FUEGO" housing) that self-adjusts for either 12- or 24-volt operation.
|
| P1224MCW |
 |
 |
P2W, P4W |
The SpectrAlert P1224MCW is a white, selectable-output horn strobe that self-adjusts for either 12- or 24-volt operation.
|
| P24110 |
 |
 |
P2R, P4R |
The SpectrAlert P24110 is a red, 24-volt horn with a built-in 110-candela strobe.
|
| P24110K |
 |
 |
P2RK, P4RK |
The SpectrAlert P24110K is a weatherproof, red, 24-volt horn with a built-in 110-candela strobe.
|
| P24110W |
 |
 |
P2W, P4W |
The SpectrAlert P24110W is a white, 24-volt horn with a built-in 110-candela strobe.
|
| P2415 |
 |
 |
P2R, P4R |
The SpectrAlert P2415 is a red, 24-volt horn with a built-in 15-candela strobe.
|
| P241575 |
 |
 |
P2R, P4R |
The SpectrAlert P241575 is a red, 24-volt horn with a built-in 15/75-candela strobe.
|
| P241575F |
 |
 |
P2R-SP |
The SpectrAlert P241575F is a red, 24-volt horn with built-in 15/75-candela strobe and "FUEGO" lettering.
|
| P241575K |
 |
 |
P2RK, P4RK |
The SpectrAlert P241575K is a weatherproof, red, 24-volt horn with a built-in 15/75-candela strobe.
|
| P241575P |
 |
 |
P2R-P, P4R-P |
The SpectrAlert P241575P is a blank, red, 24-volt horn with a built-in 15/75-candela strobe.
|
| P241575PW |
 |
 |
P2W-P, P4W-P |
The SpectrAlert P241575PW is a blank, white, 24-volt horn with a built-in 15/75-candela strobe.
|
| P241575W |
 |
 |
P2W, P4W |
The SpectrAlert P241575W is a white, 24-volt horn with a built-in 15/75-candela strobe.
|
| P2415W |
 |
 |
P2W, P4W |
The SpectrAlert P2415W is a white, 24-volt horn with a built-in 15-candela strobe.
|
| P2430 |
 |
 |
P2R, P4R |
The SpectrAlert P2430 is a red, 24-volt horn with a built-in 30-candela strobe.
|
| P2430W |
 |
 |
P2W, P4W |
The SpectrAlert P2430W is a white, 24-volt horn with a built-in 30-candela strobe.
|
| P2475 |
 |
 |
P2R, P4R, P4R |
The SpectrAlert P2475 is a red, 24-volt horn with a built-in 75-candela strobe.
|
| P2475ALP |
 |
 |
|
SpectrAlert horn strobe with amber lens
|
| P2475BLP |
 |
 |
|
SpectrAlert horn strobe with blue lens
|
| P2475GLP |
 |
 |
|
SpectrAlert horn strobe with green lens
|
| P2475RLP |
 |
 |
|
SpectrAlert horn strobe with red lens
|
| P2475K |
 |
 |
P2RK, P4RK |
The SpectrAlert P2475K is a weatherproof, red, 24-volt horn with a built-in 75-candela strobe.
|
| P2475W |
 |
 |
P2W, P4W |
The SpectrAlert P2475W is a white, 24-volt horn with a built-in 75-candela strobe.
|
| P2RH-P |
 |
 |
P2RH |
The SpectrAlert Advance P2RH-P is an unmarked, red, two-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
| P2RH-SP |
 |
 |
P2R-SP |
Marked with "FUEGO," the SpectrAlert Advance P2RH-SP is a red, two-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
| P4RH-P |
 |
 |
P4RH |
The SpectrAlert Advance P4RH-P is an unmarked, red, four-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
| P4RHK |
 |
 |
P4RK |
The SpectrAlert Advance P4RHK is a red, four-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
| P4RHK-R |
 |
 |
P4RK |
The SpectrAlert Advance P4RHK-R (replacement model) is a red, four-wire, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Offers mounting plate only - no back box included.
|
| P4WH |
 |
 |
P4W |
The SpectrAlert Advance P4WH is a white, four-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
| P4WH-P |
 |
 |
P4WH |
The SpectrAlert Advance P4WH-P is an unmarked, white, four-wire horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
| PC24115 |
 |
 |
PC2R, PC4R |
The SpectrAlert PC24115 is a red, ceiling-mount, 24-volt horn with a built-in 115-candela strobe.
|
| PC24115W |
 |
 |
PC2W, PC4W |
The SpectrAlert PC24115W is a white, ceiling-mount, 24-volt horn with a built-in 115-candela strobe.
|
| PC2415 |
 |
 |
PC2R, PC4R |
The SpectrAlert PC2415 is a red, ceiling-mount, 24-volt horn with a built-in 15-candela strobe.
|
| PC241575 |
 |
 |
PC2R, PC4R |
The SpectrAlert PC241575 is a red, ceiling-mount, 24-volt horn with a built-in 15/75-candela strobe.
|
| PC241575P |
 |
 |
PC2R-P |
The SpectrAlert PC241575P is a plain, red, ceiling-mount, 24-volt horn with a built-in 15/75-candela strobe.
|
| PC241575PW |
 |
 |
PC2W-P |
The SpectrAlert PC241575PW is a plain, white, ceiling-mount, 24-volt horn with a built-in 15/75-candela strobe.
|
| PC241575W |
 |
 |
PC2W, PC4W |
The SpectrAlert PC241575W is a white, ceiling-mount, 24-volt horn with a built-in 15/75-candela strobe.
|
| PC2415W |
 |
 |
PC2W, PC4W |
The SpectrAlert PC2415W is a white, ceiling-mount, 24-volt horn with a built-in 15-candela strobe.
|
| PC24177 |
 |
 |
PC2RH, PC4RH |
The SpectrAlert PC24177 is a red, ceiling-mount, 24-volt horn with a built-in 177-candela strobe.
|
| PC24177W |
 |
 |
PC2WH, PC4WH |
The SpectrAlert PC24177W is a white, ceiling-mount, 24-volt horn with a built-in 177-candela strobe.
|
| PC2430 |
 |
 |
PC2R, PC4R |
The SpectrAlert PC2430 is a red, ceiling-mount, 24-volt horn with a built-in 30-candela strobe.
|
| PC2430W |
 |
 |
PC2W, PC4W |
The SpectrAlert PC2430W is a white, ceiling-mount, 24-volt horn with a built-in 30-candela strobe.
|
| PC2475 |
 |
 |
PC2R, PC4R |
The SpectrAlert PC2475 is a red, ceiling-mount, 24-volt horn with a built-in 75-candela strobe.
|
| PC2475W |
 |
 |
PC2W, PC4W |
The SpectrAlert PC2475W is a white, ceiling-mount, 24-volt horn with a built-in 75-candela strobe.
|
| PC2495 |
 |
 |
PC2R, PC4R |
The SpectrAlert PC2495 is a red, ceiling-mount, 24-volt horn with a built-in 95-candela strobe.
|
| PC2495W |
 |
 |
PC2W, PC4W |
The SpectrAlert PC2495W is a white, ceiling-mount, 24-volt horn with a built-in 95-candela strobe.
|
| PC2RH-P |
 |
 |
PC2RH |
The SpectrAlert Advance PC2RH-P is an unmarked, red, two-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
| PC2RK-R |
 |
 |
|
The SpectrAlert Advance PC2RK-R (replacement model) is a red, two-wire, ceiling-mount, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Offers mounting plate only - no back box included.
|
| PC2RHK-R |
 |
 |
|
The SpectrAlert Advance PC2RHK-R (replacement model) is a red, two-wire, ceiling-mount, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Offers mounting plate only - no back box included.
|
| PC2WH-SP |
 |
 |
PC2W |
Marked with "FUEGO," the SpectrAlert Advance PC2WH-SP is a white, two-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
|
| PC4RK |
 |
 |
PC4R |
The SpectrAlert Advance PC4RK is a red, four-wire, ceiling-mount, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd.
|
| PC4RK-R |
 |
 |
PC4R |
The SpectrAlert Advance PC4RK-R (replacement model) is a red, four-wire, ceiling-mount, outdoor horn strobe with selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd. Offers mounting plate only - no back box included.
|
| PC4RHK |
 |
 |
PC4R |
The SpectrAlert Advance PC4RHK is a red, four-wire, ceiling-mount, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd. Outdoor back box included.
|
| PC4RHK-R |
 |
 |
PC4R |
The SpectrAlert Advance PC4RHK-R (replacement model) is a red, four-wire, ceiling-mount, outdoor horn strobe with selectable high-candela strobe settings of 135, 150, 177, and 185 cd. Offers mounting plate only - no back box included.
|
| PC4WH |
 |
 |
PC4W |
The SpectrAlert Advance PC4WH is a white, four-wire, ceiling-mount horn strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd.
| |