Conventional Detection
Search for: conv-accessories
RA100Z RA100Z RA100Z
RA100Z Data Sheet Data Sheet (pdf)
RA100Z Installation Instructions Installation Instructions (pdf)

RA100Z remote annunciator is designed for both conventional and intelligent applications.


SENS-RDR SENS-RDR SENS-RDR
SENS-RDR Data Sheet Data Sheet (pdf)
SENS-RDR Installation Instructions Installation Instructions (pdf)

The SENS-RDR is utilizes infrared technology to read the sensitivity of i3 Series detectors.


2W-MOD2 2W-MOD2 2W-MOD2
2W-MOD2 Data Sheet Data Sheet (pdf)
2W-MOD2 Installation Instructions Installation Instructions (pdf)
2W-MOD2 Engineering Specs Engineering Specs

The 2W-MOD2 is a two-wire loop test and maintenance module for use with i3 Series detectors. (Replaces Model No. 2W-MOD)


RT RT RT

The RT is an installation/removal tool for use with i3 Series detectors.
Detector removal tool guide


RRS-MOD RRS-MOD RRS-MOD
RRS-MOD Data Sheet Data Sheet (pdf)
RRS-MOD Installation Instructions Installation Instructions (pdf)
RRS-MOD Engineering Specs Engineering Specs

The RRS-MOD is a reversing relay/synchronization module for use with i3 Series detectors with built-in sounder.


A77-AB A77-AB A77-AB
A77-AB Data Sheet Data Sheet (pdf)

The A77-AB Adapter Bracket allows installers to retrofit applications where a larger diameter detector was previously installed.


A77-AB2 A77-AB2 A77-AB2

The A77-AB2 allows installers to retrofit i3 Series detectors where a larger diameter detector was previously installed.


MOD400R MOD400R MOD400R
MOD400R Data Sheet Data Sheet (pdf)
MOD400R Installation Instructions Installation Instructions (pdf)

The MOD400R is used to check the sensitivity of System Sensor 100, 200, 400, and 500 Series smoke detectors, and DH100, DH200, DH400, and DH500 Series duct smoke detectors.


SMB600 SMB600 SMB600
SMB600 Data Sheet Data Sheet (pdf)
SMB600 Installation Instructions Installation Instructions (pdf)

The SMB600 flanged surface mounting kit may be used with certain System Sensor smoke detectors when flush or recessed mounting are not possible.


XR2 XR2 XR2
XR2 Installation Instructions Installation Instructions (pdf)

The XR2 is an installation/removal tool for use with previous models of the 100 and 200 series plug-in smoke detectors.
Detector removal tool guide


BEAMMMK BEAMMMK BEAMMMK
BEAMMMK Installation Instructions Installation Instructions (pdf)

Multi-mount kit (Provides ceiling or wall mount capability with increased angular adjustment for either the beam or the reflector. When installed with the transmitter/receiver unit, BEAMSMK must be used as well)


6500-MMK 6500-MMK 6500-MMK
6500-MMK Installation Instructions Installation Instructions (pdf)

Heavy duty multi-mount kit (for installations prone to vibration or where there is difficulty in maintaining the set angle. When installed with the transmitter/receiver unit, 6500-SMK must be used as well)


BEAMSMK BEAMSMK BEAMSMK
BEAMSMK Installation Instructions Installation Instructions (pdf)

Surface-mount kit for BEAM1224(S) and BEAM200(S) when using the BEAMMMK Multi-Mount Kit or when mounting over a recessed junction box.


6500-SMK 6500-SMK 6500-SMK
6500-SMK Installation Instructions Installation Instructions (pdf)

Surface-mount kit for use with the BEAM1224 and BEAM200 when using the 6500-MMK Heavy Duty Multi-Mount Kit


BEAMLRK BEAMLRK BEAMLRK
BEAMLRK Installation Instructions Installation Instructions (pdf)

Long-range kit for BEAM1224 and BEAM200


BEAMHK BEAMHK BEAMHK
BEAMHK Installation Instructions Installation Instructions (pdf)

Heating kit for use with the transmitter/receiver unit of System Sensor reflective projected beam smoke detectors


BEAMHKR BEAMHKR BEAMHKR
BEAMHKR Installation Instructions Installation Instructions (pdf)

Heating kit for use with the reflector of System Sensor reflective projected beam smoke detectors


CO-PLATE CO-PLATE CO-PLATE
CO-PLATE Data Sheet Data Sheet (pdf)
CO-PLATE Installation Instructions Installation Instructions (pdf)

CO detector replacement plate to cover the footprint of previously installed detectors.



Discontinued Products
Discontinued Model Installation Instructions Data Sheet Replacement Model
RA400Z RA400Z Brochure   RA100Z
The RA400Z is a remote annunciator for use with both conventional and intelligent smoke detectors.
RMK400 RMK400 Brochure RMK400 Data Sheet  
The RMK400 Recessed Mounting Kit is for use with System Sensor 100, 200, 400, and 500 Series plug-in detectors.
RR2 RR2 Brochure RR2 Data Sheet  
The RR2 allows all detectors on a loop to sound when one goes into alarm.
RR1 RR1 Brochure    
Polarity reversing relay module intended for use with 2- and 4-wire detectors with built-in sounder
SMK400 SMK400 Brochure SMK400 Data Sheet  
The SMK400 flangeless surface mounting kit may be used with certain System Sensor smoke detectors when flush or recessed mounting are not possible.