Intelligent Detection Product Line

Smoke DetectorsDuct Smoke DetectorsBeam Smoke DetectorsThermal
EclipseModulesBasesPinnacleMulti-CriteriaAccessories

Intelligent Detection
Search for: intell-accessories
F110 F110 F110

Retrofit Flange Ring for 6" base, B210LP


F210 F210 F210

New Smaller Flange Ring for 6" base, B210LP


CB500 CB500 CB500
CB500 Installation Instructions Installation Instructions (pdf)

The CB500 barrier is used to separate power limited and non-power limited wiring in a junction box.


RA100Z RA100Z RA100Z
RA100Z Data Sheet Data Sheet (pdf)
RA100Z Installation Instructions Installation Instructions (pdf)

RA100Z remote annunciator is designed for both conventional and intelligent applications.


SMB500 SMB500 SMB500
SMB500 Installation Instructions Installation Instructions (pdf)

The SMB500 surface mount box may be used with certain System Sensor modules when flush or recessed mounting are not possible.


XR2 XR2 XR2
XR2 Data Sheet Data Sheet (pdf)

The XR2 is an installation/removal tool for use with previous models of the 100 and 200 series plug-in smoke detectors.
Detector removal tool guide


SYNC-1 SYNC-1 SYNC-1
SYNC-1 Data Sheet Data Sheet (pdf)
SYNC-1 Installation Instructions Installation Instructions (pdf)

Accessory card used with the SC-6 to provide synchronization of SpectrAlert horns and strobes


BCK-200B BCK-200B BCK-200B
BCK-200B Data Sheet Data Sheet (pdf)

Black detector kit for 200 Series detectors


WCK-200B WCK-200B WCK-200B
WCK-200B Data Sheet Data Sheet (pdf)

White detector kit for 200 Series detectors


M02-09-00 M02-09-00 M02-09-00
M02-09-00 Data Sheet Data Sheet (pdf)

Test magnet with telescoping handle


XR2B XR2B XR2B
XR2B Data Sheet Data Sheet (pdf)
XR2B Installation Instructions Installation Instructions (pdf)

The XR2B is a removal and replacement tool for current models of the 100 and 200 series plug-in smoke detectors.
Detector removal tool guide


BEAMMMK BEAMMMK BEAMMMK
BEAMMMK Installation Instructions Installation Instructions (pdf)

Multi-mount kit (Provides ceiling or wall mount capability with increased angular adjustment for either the beam or the reflector. When installed with the transmitter/receiver unit, BEAMSMK must be used as well)


6500-MMK 6500-MMK 6500-MMK
6500-MMK Installation Instructions Installation Instructions (pdf)

Heavy duty multi-mount kit (for installations prone to vibration or where there is difficulty in maintaining the set angle. When installed with the transmitter/receiver unit, 6500-SMK must be used as well)


BEAMSMK BEAMSMK BEAMSMK
BEAMSMK Installation Instructions Installation Instructions (pdf)

Surface-mount kit for BEAM1224(S) and BEAM200(S) when using the BEAMMMK Multi-Mount Kit or when mounting over a recessed junction box.


6500-SMK 6500-SMK 6500-SMK
6500-SMK Installation Instructions Installation Instructions (pdf)

Surface-mount kit for use with the BEAM1224 and BEAM200 when using the 6500-MMK Heavy Duty Multi-Mount Kit


BEAMLRK BEAMLRK BEAMLRK
BEAMLRK Installation Instructions Installation Instructions (pdf)

Long-range kit for BEAM1224 and BEAM200


EA-CB EA-CB EA-CB
EA-CB Installation Instructions Installation Instructions (pdf)

The EA-CB barrier is used to separate power limited and non-power limited wiring in a junction box.


EA-CT EA-CT EA-CT
EA-CT Installation Instructions Installation Instructions (pdf)

Eclipse Series Configuration Tool


XP-4 XP-4 XP-4
XP-4 Data Sheet Data Sheet (pdf)
XP-4 Installation Instructions Installation Instructions (pdf)

Extension pole for XR2B (5-15 ft.)


M02-04-00 M02-04-00 M02-04-00
M02-04-00 Data Sheet Data Sheet (pdf)

Detector test magnet


BEAMHK BEAMHK BEAMHK
BEAMHK Installation Instructions Installation Instructions (pdf)

Heating kit for use with the transmitter/receiver unit of System Sensor BEAM200 reflective projected beam smoke detectors


BEAMHKR BEAMHKR BEAMHKR
BEAMHKR Installation Instructions Installation Instructions (pdf)

Heating kit for use with the reflector of System Sensor reflective projected beam smoke detectors (BEAM200)



Discontinued Products
Discontinued Model Installation Instructions Data Sheet Replacement Model
RA400Z RA400Z Brochure RA400Z Data Sheet RA100Z
Remote annunciator for duct and beam detectors
RTS451 RTS451 Brochure   RTS151
Magnetic remote test and reset station for duct and beam detector
RTS451KEY RTS451KEY Brochure   RTS151KEY
Key remote test and reset station for duct and beam detector